| Installation and User Instructions | ISO7240-16: 2007
en
| 76
Clause / Requirement
Compliance
Signature
14 Design requirements
14.2 Documentation
14.2.1
The manufacturer shall prepare installation and user
documentation, which shall be submitted to the testing
authority together with the s.s.c.i.e. This shall comprise at least
the following:
b technical specifications of the inputs and outputs of the
s.s.c.i.e., sufficient to permit an assessment of the
mechanical, electrical, and software compatibility with other
components of the system (e.g. as described in
ISO 7240-1), including where relevant
3 the maximum number of alarm inputs from an emergency
detection system
The inputs and outputs for audio and control are described in
the IUI, including the technical data, system functions,
configuration instructions, compliancy to standards. This
includes the information as requested in 14.2.1 b 3.
c installation information, including
The IUI contains all information as requested in 14.2.1 c
1-5.
1 the suitability for use in various environments,
2 how the requirements of 14.3.3 and 14.5.3 can be met if
the s.s.c.i.e. is contained in more than one cabinet,
3 how the requirements of 14.3.3 and 14.5.4 can be met if
the s.s.c.i.e is designed to be used with power-supply
equipment contained in a separate cabinet,
4 mounting instructions, and
5 instructions for connecting the inputs and outputs.
14.3.3
The s.s.c.i.e. may be housed in more than one cabinet. If
the documentation shows that the cabinets may be installed in
locations distributed within a site, then all of the mandatory
manual controls and indicators shall be on one cabinet or on
cabinets declared to be suitable only for mounting adjacent to
each other.
NOTE
For the purposes of 14.3.3, adjacent cabinets are those
that are mounted in physical contact with each other.
In case Praesideo is installed in multiple cabinets in locations
distributed within a site, the installer must arrange that all
mandatory manual controls and indicators are on the same
location, either by installing them on a single cabinet or on
adjacent cabinets that are mounted in physical contact with
each other.
14.8 Indications on alphanumeric displays
14.8.2
Alphanumeric displays used for mandatory indications
shall have at least one clearly distinguishable window,
consisting of at least two clearly identifiable fields.
The display of the network controller is used to display
mandatory indications. It consists of two separate lines of text,
each representing a specific field, clearly identifiable.
14.8.3
If not included in the displayed information, the purpose
of each field shall be clearly labelled.
Indication of the voice alarm condition is by means of the text
'Emergency' and the name of the key that activated the voice
alarm condition. Indication of the fault warning condition is by
means of the text 'Faults' and an indication of the number of
active faults in the system. Individual faults with details are
shown in a menu structure.
14.8.4
Where roman characters are used, a field shall be
capable of containing at least the following:
a at least 16 characters where the display of a functional
condition uses a cross-reference to other information to
identify the location;
The display of the network controller consists of two lines with
16 characters each. It uses a menu with rotary knob navigation
to select additional detailed information about functional
conditions.
b at least 40 characters where the display is intended to
include the complete information on the location of a
functional condition.
Not applicable, see 14.8.4.a.
14.8.5
Where other characters are used, a field shall be
capable of containing at least the following:
Not applicable, see 14.8.4.
a at least 4 characters where the display of a functional
condition uses a cross-reference to other information to
identify the location;
b at least 8 characters where the display is intended to include
the complete information on the location of a functional
condition.
14.9 Colours of indications
14.9.1
The colours of the general and specific indications from
light-emitting indicators shall be as follows:
b yellow for indications of
3 emergency loudspeaker zones in the test state.
The test condition is an optional function and is not supported
by Praesideo. See 10.