Инструкция по эксплуатации EXFO FTB -5240S/5240BP Optical Spectrum Analyzer for FTB 500 (NS-1434)

Страница 482

Advertising
background image

Справка по командам SCPI

476

FTB-5240S/S-P/BP

Product-Specific Commands—Description

DEFault allows the instrument to select a value
for the <Distance> parameter.

The <Distance> parameter corresponds to a valid
distance in meter from peak to center of noise
region.

The
CALCulate[1..n][:WDM]:CHANnel:NOISe:DISTan
ce[:WAVelength]? MIN and
CALCulate[1..n][:WDM]:CHANnel:NOISe:DISTan
ce[:WAVelength]? MAX queries can be used to
determine valid distance values.

Example(s)

CALC:WDM:CHAN:DEF "CWDM_3",1410.0 NM
CALC:WDM:CHAN:SEL "CWDM_3"
CALC:WDM:CHAN:NOIS:TYPE POLY5
CALC:WDM:CHAN:NOIS:DIST:WAV 40.0 NM
CALC:WDM:CHAN:NOIS:DIST:WAV? Returns
4.000000E-008

Notes

Custom noise measurement distance is applied
only if selected noise type is POLYnomial5.

See Also

:CALCulate[1..n][:WDM]:CHANnel:NOISe:DISTa
nce:FREQuency
:CALCulate[1..n][:WDM]:CHANnel:NOISe:DISTa
nce[:WAVelength]?
:CALCulate[1..n][:WDM]:CHANnel:NOISe:WIDTh
[:WAVelength]

:CALCulate[1..n][:WDM]:CHANnel:NOISe:TYPE
:CALCulate[1..n][:WDM]:CHANnel:SELect
:CALCulate[1..n][:WDM]:CHANnel:AUTO:NOISe:
DISTance[:WAVelength]

:CALCulate[1..n][:WDM]:CHANnel:

NOISe:DISTance[:WAVelength]

Advertising