Appendix, Troubleshooting, General – Инструкция по эксплуатации Yamaha RX-V2065

Страница 67

Advertising
background image

65

En

English

INTR

ODUCTION

APPENDIX

PRE

P

ARA

T

ION

BA

S

IC

OPERA

T

ION

AD

V

ANCED

OPERA

T

ION

APPENDIX

Refer to the table below when this unit does not function properly. If the problem you are experiencing is not listed below
or if the instruction below does not help, turn off this unit, disconnect the power cable, and contact the nearest authorized
Yamaha dealer or service center.

Troubleshooting

General

Problem

Cause

Remedy

See

page

This unit does not

operate properly.

The internal microcomputer is frozen due

to an external electric shock (such as

lightning or excessive static electricity) or

by a drop in power supply voltage.

Disconnect the power cable from the AC wall outlet,

wait about 30 seconds and then plug it in again.

This unit suddenly

enters the standby

mode

The internal temperature is too high and

the overheat protection circuitry has been

activated.

Wait about 1 hour for this unit to cool down and then

turn it back on.

The protection circuitry has been activated

because of a short circuit, etc.

Check that the speaker impedance setting is correct.

63

Check that the speaker wires are not touching each

other and then turn this unit back on.

The sleep timer has turned off this unit.

Turn on this unit and play the source again.

This unit fails to turn

on or enters the

standby mode soon

after the power is

turned on.

The power cable is not connected or the

plug is not completely inserted.

Connect the power cable properly to an AC wall

outlet.

20

The speaker impedance setting is

incorrect.

Set the speaker impedance to match your speakers.

63

(When this unit is turned back on and

“CHECK SP WIRES!” is displayed.) The

protection circuitry has been activated

because this unit was turned on while a

speaker cable was shorted.

Make sure that all speaker cables between this unit

and speakers are connected properly.

11

This unit cannot be

turned off.

The internal microcomputer is frozen due

to an external electric shock (such as

lightning or excessive static electricity) or

by a drop in power supply voltage.

Disconnect the power cable from the AC wall outlet,

wait about 30 seconds and then plug it in again.

Advertising