In the advanced setup menu, you can set basic operations
of this unit, such as on and off of a bi-amp connection, or
initialize user settings.

1

Set this unit to standby.

2

While holding down QSTRAIGHT on the
front panel, press
LMAIN ZONE ON/OFF.
Keep holding down QSTRAIGHT until
“ADVANCED SETUP” appears on the front panel
display.

3

Rotate the PPROGRAM selector to select
the parameter you want to change.
The default setting are marked with “*”.

y

• Set values are placed in XXX of the following parameters on an

actual display screen.

SP IMP. -XXX

Selects output impedance of this unit according to
connected speakers. When you connect 4-ohm
speakers to the FRONT speaker terminals, set “SP
IMP.” to “6

ΩMIN.”.

RS232C STBY -X

Selects whether or not to transmit data via the RS-
232C terminal when this unit is in the standby mode.

REMOTE ID -XXX

Sets a remote control ID. When using multiple
Yamaha AV receivers, you can operate them with a
single remote control by setting the receiver IDs to
the same setting.

BI AMP - XXX

Switches on and off of bi-amp connection of main
speakers. For bi-amp connection, see page 12.

SCENE IR -XXX

Selects whether or not to transmit the control signals
to an external component connected to the REMOTE
OUT jack on this unit when BD/DVD or CD SCENE
function is selected.

MON.CHK - XXXX

Adds upscaling limitation on output signals to a video
monitor connected to this unit via the HDMI OUT
jack.

INIT-XXXXXXXXX

Initializes various settings stored in this unit. You can
select an initialization method from the following.
DSP PARAM: All parameters of sound field

programs

VIDEO

Video conversion settings (resolution/
aspect) in the Setup menu and the GUI
display position

NETWORK

Network settings in the Setup menu

ALL

All

CANCEL

Cancellation of initialization

USB FirmUpdate
NET FirmUpdate

Updates the firmware of this unit. For details on how
to update the firmware, refer to information supplied
with updates.

Notes

• Do not use this feature unless you need to update the firmware.
• Be sure to read information supplied with updates before updating

the firmware.

VERXXX.XXX.XXX

Displays the firmware of this unit.

4

Press QSTRAIGHT repeatedly to change
the selected parameter setting.
To change other settings, repeat steps 3 and 4.

5

Press LMAIN ZONE ON/OFF to set this
unit to standby.
The settings you made are reflected next time you
turn on this unit.

Advanced setup

Choices: 6

ΩMIN, 8ΩMIN*

Choices: Y (Yes), N (No)*

Choices: ID1*, ID2

Choices: ON, OFF*

Choices: ON*, OFF

Choices: YES*, SKIP

ADVANCED SETUP

Choices: DSP PARAM, VIDEO, NETWORK, ALL,

CANCEL*