4 устранение неисправностей ddm – Инструкция по эксплуатации QTECH QSW-3400 Руководство администратора

Страница 111

Advertising
background image

Руководство пользователя

14. Настройка DDM

111

www.qtech.ru

The current time is Jan 02 12:30:50 2011.

The last threshold-violation time is Jan 02 11:00:50 2011.

Brief alarm information:

RX loss of signal

RX power low

Detail diagnostic and threshold information:

Diagnostic Threshold

Realtime Value High Alarm Low Alarm High Warn Low Warn

------------ ----------- ----------- ------------ ---------

Temperature(°С) 33 70 0

70 0

Voltage(V)

7.31

10.00

0.00

5.00 0.00

Bias current(mA) 3.11 10.30

0.00

5.00 0.00

RX Power(dBM) -30.54(A-) 9.00

-25.00(-34)

9.00 -25.00

TX Power(dBM) -1.01

9.00

-12.05

9.00 -10.00

Ethernet 1/22 transceiver threshold-violation information:

Transceiver monitor is disabled. Monitor interval is set to 30
minutes.

The last threshold-violation doesn’t exist.

14.4 Устранение неисправностей DDM

Если возникают проблемы при настройке DDM, пожалуйста, проверьте, является ли эта
проблема следствием следующих причин:

Убедитесь, что трансивер на оптическом модуле был включен на порте, иначе
конфигурация DDM не будет показана.

Убедитесь, что конфигурация SNMP работает, иначе оповещение о событии не

сможет оповестить систему сетевого управления.

Не все коммутаторы поддерживают SFP с DDM или XFP с DDM, убедитесь в

использовании коммутатора с поддержкой соответствующей функции.

Использование команд show transceiver или show transceiver detail может занять
много времени, так как коммутатор будет проверять все порты, поэтому

рекомендуется запрашивать информацию о трансивере на определенный порт.

Убедитесь, что установленный пользователем порог является действующим. При

любой ошибке порогового значения трансивер будет посылать сигнализацию в

соответствии со значением, установленным по умолчанию.