Reduced tap flow, Part 9, Gas convertion – Инструкция по эксплуатации Beko CS 47100

Страница 30

Внимание! Текст в этом документе был распознан автоматически. Для просмотра оригинальной страницы Вы можете воспользоваться режимом "Оригинал".

Advertising
background image

A

Part 9:

Gas convertion

Your cooker can operate both Natural Gas

and LPG. You can convert by changing the
gas source and the top burner, oven and grill

injectors. The replacement procedure of the
injectors are explained below.
Call authorized Service for gas convertion.

Replacement of the top burner

injector

Take off the burner head and burner cap

before starting this procedure. Then:

1. Remove the injector inside the top burner

with a suitable bit. Later, install the new

injector by covering the injector threads

with leakage

preventing

material.

Reduced Tap Flow

Removal of the knob

1.Ignite the burner that should be

adjusted, turn the knob to the reduced

position, pull and take the knob off.

2.

With a screwdriver, make the tap

reduced flow adjustment from the
injector that is on the gas tap (only

the head is visible with the bolt shape).

It is sufficient to tight to screw

completely, in butane/propane gas.

For the natural gas, you should turn

the screw counter-clockwise once. The

normal length of a straight flame in

the reduced position should be 6 -

7mm.

If the flame is higher than the desired
position, turn the screw clockwise. If
its smaller to the opposite.
For the last control of the burning of

the cooker, bring the cooker high-
flame and reduced positions and check
whether the f l a m e i s o n o r o f f .

29

Advertising