13. Настройка DDM

120

www.qtech.ru

The current time is Jan 02 12:30:50 2011.

The last threshold-violation time is Jan 02 11:00:50 2011.

Brief alarm information:

RX loss of signal

RX power low

Detail diagnostic and threshold information:

DiagnosticThreshold Realtime Value High AlarmLow Alarm High Warn Low Warn

----------------------- ----------- ------------ ---------

Temperature(°С)

33

70

0

70 0

Voltage(V)

7.31 10.00 0.00

5.00 0.00

Bias current(mA)

3.11 10.30 0.00

5.00 0.00

RX Power(dBM)

-30.54(A-)

9.00 -25.00(-34) 9.00 -25.00

TX Power(dBM)

-1.01 9.00 -12.05

9.00 -10.00

Ethernet 1/22 transceiver threshold-violation information:

Transceiver monitor is disabled. Monitor interval is set to 30 minutes.

The last threshold-violation doesn’t exist.

13.4 Устранние неисправностей DDM

Если возникают проблемы при настройке DDM, пожалуйста, проверьте является ли эта
проблема следствием следующих причин:

Убедитесь, что трансивер на оптическом модуле был включен на порте, иначе

конфигурация DDM не пудет показана.

Убедитесь, что конфигурация SNMP работает, иначе оповещение о событии не
сможет оповестить систему сетевого управления.

Не все коммутаторы поддерживают SFP с DDM или XFP с DDM, убедитесь в

использовании коммутатора с поддержкой соответствующей функции.

Использование команд show transceiver или show transceiver detail может занять

много времени, так как коммутатор будет проверять все порты, поэтому

рекомендуется запрашивать информацию о трансивере на определенный порт.

Убедитесь, что установленный пользователем порог явлется действующим. При

любой ошибке порогового значения трансивер будет позылать сигнализацию в

соответствии со значением, установленным по умолчанию.