1. The unit installation work must be done by qualified personnel according to the
local rules and this manual.
2. If the air conditioner has not plug, directly connect it into the fixed circuit, a
breaker should be installed in the fixed circuit. all pole of this breaker should be
switching off and the distance of the contact should be at least 3 mm.
Install in the following place may cause malfunction. If it is unavoidable contact
with service center please:
• Place where strong heat sources, vapors, flammable gas or volatile object are
emitted.
• Place where high-frequency waves are generated by radio equipment, weld-
ers and medical equipment.
• Place where a lot of salinities such as coast exists.
• Place where the oil (machine oil) is contained in the air.
• Place where a sulfured gas such as the hot spring zones is generated.
• Other place with special circumstance.
1. The air inlet and outlet vent should be far from the obstruction, make sure that
the air can be blown through the whole room.
2. Select a position where the condensing water can be easily drained out, and
the place is easily connected for outdoor unit.
3. Select a location where the children can not reach.
4. Can select the place where is strong enough to withstand the full weight and
vibration of the unit. And will not increase the noise.
5. Be sure to leave enough space to allow access for routine maintenance. The
height of the installed location should be 230 cm or more from the floor.
6. Select a place about 1m or more away from TVset or any other electric appli-
ances.
7. Select a place where the filter can be easily taken out.
8. Make sure that the indoor unit installation should accord with installation di-
mension diagram requirements.
1. Select a location from which noise and outflow air emitted by unit will not incon-
venience neighbors, animals, plants.
2. Select a location where there should be sufficient ventilation.
3. Select a location where there should be no obstructions cover the inlet and
outlet vent.
4. The location should be able to withstand the full weight and vibration of the
outdoor unit and permit safe installation.
5. Select a dry place, but do not expose under the direct sunlight or strong wind.
6. Make sure that the outdoor unit installation dimension should accord with in-
stallation dimension diagram, convenient for maintenance, repair.
7. The height difference of connecting the tubing within 5m, the length of con-
necting the tubing within 10 m.
8. Select a place where it is out of reach for the children.
IMPORTANT NOTICES
BASIC REQUIREMENTS FOR INSTALLATION POSITION
INDOOR UNIT INSTALLATION POSITION SELECTION
OUTDOOR UNIT INSTALLATION POSITION SELECTION