Инструкция по эксплуатации Elenberg SPT-7090

Страница 37

Advertising
background image

37

Wireless remote control is

not available.

• The unit is interfered by abnormal or frequent func-

tions switch over occasionally the controller cannot

operate. At this time, you need to pull out of the

plug, and reinsert it.

• Is it in its receiving range? Or obstructed?

• To check the voltage in wireless remote control in-

side is charged, otherwise to replace the batteries.

• Whether the wireless remote control is damaged.

If water leakage in the

room.

• The air humidity is on the high side.

• Condensing water over flowed.

• The connection position of indoor unit drainage

pipe is loosed.

If water leakage in out-

door unit.

• When the unit is running in COOL mode, the pipe

and connection of pipe would be condensed due

to the water cooled down.

• When the unit is running in Auto Defrosting mode,

the ice thawed and flowed out.

• When the unit is running in HEAT mode, the water

adhered on heat exchanger dripped off.

Noise from indoor unit

emitted.

• The sound of fan or compressor relay is switching on

or off.

• When the defrosting is started or stop running, it will

sound. That is due to the refrigerant flowed to the

reverse direction.

Indoor unit cannot de-

liver air.

• In dehumidifying mode, sometimes indoor fan will

stop, in order to avoid condensing water be vapor-

ized again, restrain temperature rising.

• In HEAT mode, when the temperature of indoor

heat exchanger is very low, that will stop deliver air

in order to prevent cool air. (Within 3 min)

• In HEAT mode, when the outdoor temperature is low

or high humidity, there are much frost be formed

on the outdoor heat exchanger, that the unit will

automatically defrost, indoor unit stop blowing air

for 3-12 mins. During the defrosting, there is water

flowing out or vapor be produced.

Moisture on air outlet

vent.

If unit is running under the high humidity for a long

time, the moisture will be condensed on the air outlet

grill and drip off.

Immediately stop all operations and plug out, contact the dealer in following situa-

tions:

• There is harsh sound during operation.

• The terrible odors emitted during operation.

• Water is leaking in the room.

• Air switch or protection switch often breaks.

• Carelessy splash water or something into unit.

• There is an abnormal heat in power supply cord and power plug.

Advertising