intportanf instaliation and preparation of your oven

*■ Before your appliance is connected to the

mains electricity supply, check to ensure that
the voltage and the frequency shown in the
data plate corresponds with your power supply.

The data plate is situated back cover of the

oven, or it is situated in the front of the storage
compartment and can be seen by opening the
storage compartmenf cover or pdling the drawer.

WuHiiugl

This appliance must be earthed

Our company shall not held responsible for any
damage caused by the utilisation of the oven
without ground socket.

Before applying to Authorized service, have

the electrical wiring of your home ready for
connection.
If the appliances is
connecfed by a plug, that
the plug is easily accessible after installation

(but not above the hob)

iS'This product must only be installed by a

qualified electrician eg. local electricity company
to a suitable double pole control unit with a
minimum coritact cfearonce of 3 mm in all poles
which should be adjacent to (but not above)
the cooker in accordance with lEE regulation,
FaiVure fo observe this /nsfruciion may result in
operational problems and invalidation of the

product warranty. If the appliance is connected

by a plug, that the plug is easily accessible
after insfoi/afibn (but not above the hob).

The cable length should be 2 mt max for isohlion

safety.

In models with "small type- terminal block"

In mix models a cable supplied with a plug with

your

oven

(H05 V V-F 3G 1.5 mm2)

If a cable without a plug is provided fogefber

with your oven (H05 V V-F 3G 2,5 mm2 ]
Jake care fo

connecf os

below:

Brown cable = L (Live)
Blue cable
= N (Neutral)
Green/Ve/iow cable = E (Earth )

If your oven is supplied without supply cord use

sc/iema-/ to choose supply cord and use scbemo-

II for installation of cord.
The cable length should be max 2m long for

isolation safety.

i^Open the ferminol block cover.
'•‘Connect the supply cable according to wiring diagram on the rear

cover.

Fix the supply cable to main body with integrated screw via cable

tightener.

Assembly the terminal block cover to its place.

Vour

oven is suitable for single and three phase connection.

TJ

e

p-“ rE

3NAC 3BD,MCCi^15V

3 _Li —

I

t

. if

2NAC ^eCL'ADafAISV

Schema II

o

i*~The mains cable must pass through the cable clamp.
'•'The mains cable should be
roofed owoy from the opplionce and -
particular venfi/ofion slots, the vent outlet and should not be ofasfrucfed wben
pushed in to position between the appliance and the wall and/or cobinef.

ii

®

Connection Type

A^o nopbase

Three phase

with Neutral

Two pbose

with Neufral

Voltage

220/230/
240 V

380/400/

415 V

380/400/

415 V

Supply cord type

(max 2 m lo ngj

3x2,5 mm2

H05 V V-F

5x2,5 mm2