intportanf instaliation and preparation of your oven
*■ Before your appliance is connected to the
mains electricity supply, check to ensure that
the voltage and the frequency shown in the
data plate corresponds with your power supply.
The data plate is situated back cover of the
oven, or it is situated in the front of the storage
compartment and can be seen by opening the
storage compartmenf cover or pdling the drawer.
WuHiiugl
This appliance must be earthed
Our company shall not held responsible for any
damage caused by the utilisation of the oven
without ground socket.
Before applying to Authorized service, have
the electrical wiring of your home ready for
connection.
If the appliances is connecfed by a plug, that
the plug is easily accessible after installation
(but not above the hob)
iS'This product must only be installed by a
qualified electrician eg. local electricity company
to a suitable double pole control unit with a
minimum coritact cfearonce of 3 mm in all poles
which should be adjacent to (but not above)
the cooker in accordance with lEE regulation,
FaiVure fo observe this /nsfruciion may result in
operational problems and invalidation of the
product warranty. If the appliance is connected
by a plug, that the plug is easily accessible
after insfoi/afibn (but not above the hob).
The cable length should be 2 mt max for isohlion
safety.
In models with "small type- terminal block"
In mix models a cable supplied with a plug with
your
oven
(H05 V V-F 3G 1.5 mm2)
If a cable without a plug is provided fogefber
with your oven (H05 V V-F 3G 2,5 mm2 ]
Jake care fo
connecf os
below:
Brown cable = L (Live)
Blue cable = N (Neutral)
Green/Ve/iow cable = E (Earth )
If your oven is supplied without supply cord use
sc/iema-/ to choose supply cord and use scbemo-
II for installation of cord.
The cable length should be max 2m long for
isolation safety.
i^Open the ferminol block cover.
'•‘Connect the supply cable according to wiring diagram on the rear
cover.
Fix the supply cable to main body with integrated screw via cable
tightener.
Assembly the terminal block cover to its place.
Vour
oven is suitable for single and three phase connection.
TJ
e
H©
p-“ rE
3NAC 3BD,MCCi^15V
3 _Li —
I
t
. if
2NAC ^eCL'ADafAISV
Schema II
o
i*~The mains cable must pass through the cable clamp.
'•'The mains cable should be roofed owoy from the opplionce and -
particular venfi/ofion slots, the vent outlet and should not be ofasfrucfed wben
pushed in to position between the appliance and the wall and/or cobinef.
”
ii
®
Connection Type
A^o nopbase
Three phase
with Neutral
Two pbose
with Neufral
Voltage
220/230/
240 V
380/400/
415 V
380/400/
415 V
Supply cord type
(max 2 m lo ngj
3x2,5 mm2
H05 V V-F
5x2,5 mm2
H05 V V-F
4x2,5 mm2
H05 V V-F