P a r t 9 : G a s c o n v e r t i o n
Your cooker can operate both Natural Gas and LPG.
You can convert by changing the gas source and the
top burner, oven and grill injectors. The replacement
procedure
of
the
injectors
are
explained
below.
Call authorized Service for gas convertion.
Replacement of the top burner
injector
Take off the burner head and burner cap before
starting this procedure. Then:
1. Remove the injector inside the top burner with
a suitable bit. Later, install the new injector by
covering the injector threads
with leakage
preventing
Flame failure
material.
spark plug
Reduced Tap Flow
1-lgnite the burner that should be
adjusted, turn the knob to the reduced
position, pull and take the knob off.
2.
With a screwdriver, make the tap
reduced flow adjustment from the
injector that is on the gas tap (only the
head is visible with the bolt shape).
It is sufficient to tight to screw
completely, in butane/propane gas.
For the natural gas, you should turn the
screw counter-clockwise
once. The normal length of a straight
flame in the reduced position
hould be 6 - 7mm.
If the flame is higher than the desired
position, turn the screw clockwise. If its
smaller to the opposite.
For the last control of the burning of the
cooker, bring the cooker high-flame and
reduced positions and check whether the
flame is on or off.
3 1