Gas conversion, Injector table, page 7 – Инструкция по эксплуатации Beko GG 15120 DX

Страница 78

Внимание! Текст в этом документе был распознан автоматически. Для просмотра оригинальной страницы Вы можете воспользоваться режимом "Оригинал".

Advertising
background image

falling off and poor cooking

performance if the cooker is not
level.

1

Foot

2

Foot housing

Final check

1. Check electrical functions.

2. Turn on gas supply.
3. Check gas installations for secure

fitting and tightness.

4. Ignite burners and check

appearance of the flame.

m

The flames should be blue and

burn smoothly. If the flames

appear yellowish, check secure

position of the burner cap or

clean the burner. Switch off gas
and let burner cool before

touching it.

Gas conversion

A Risk of explosion!

Before starting any work on the

gas installation, please shut off

the gas supply.

In order to change your appliance's

gas type, change all injectors and

make flame adjustment for all valves at
reduced flow rate position.

Exchange injector for the burners

1. Take off burner cap and burner

body.

2. Unscrew injectors.
3. Fit new injectors.

4. Check all connections for secure

fitting and tightness.

m

New injectors have their

position marked on their
packing or injector table on

Injector table, page 7

can be

referred to.

1

Flame failure device (model

dependant)

2

Sparking plug

3

Injector

4

Burner

[D Unless there is an abnormal

condition, do not attempt to

remove the gas burner taps. You
must call an Authorised service

agent if it is necessary to change

the taps.

Reduced gas flow rate setting for

hob taps

1

.

2

.

3.

Ignite the burner that is to be

adjusted and turn the knob to the

reduced position.
Remove the knob from the gas tap.
Use an appropriately sized

screwdriver to adjust the flow rate
adjustment screw.

16| EN

Advertising