Gas conversion, Injector table, page 7 – Инструкция по эксплуатации Beko GG 15120 DX
Страница 78
Внимание! Текст в этом документе был распознан автоматически. Для просмотра оригинальной страницы Вы можете воспользоваться режимом "Оригинал".
falling off and poor cooking
performance if the cooker is not
level.
1
Foot
2
Foot housing
Final check
1. Check electrical functions.
2. Turn on gas supply.
3. Check gas installations for secure
fitting and tightness.
4. Ignite burners and check
appearance of the flame.
m
The flames should be blue and
burn smoothly. If the flames
appear yellowish, check secure
position of the burner cap or
clean the burner. Switch off gas
and let burner cool before
touching it.
Gas conversion
A Risk of explosion!
Before starting any work on the
gas installation, please shut off
the gas supply.
In order to change your appliance's
gas type, change all injectors and
make flame adjustment for all valves at
reduced flow rate position.
Exchange injector for the burners
1. Take off burner cap and burner
body.
2. Unscrew injectors.
3. Fit new injectors.
4. Check all connections for secure
fitting and tightness.
m
New injectors have their
position marked on their
packing or injector table on
Injector table, page 7
can be
referred to.
1
Flame failure device (model
dependant)
2
Sparking plug
3
Injector
4
Burner
[D Unless there is an abnormal
condition, do not attempt to
remove the gas burner taps. You
must call an Authorised service
agent if it is necessary to change
the taps.
Reduced gas flow rate setting for
hob taps
1
.
2
.
3.
Ignite the burner that is to be
adjusted and turn the knob to the
reduced position.
Remove the knob from the gas tap.
Use an appropriately sized
screwdriver to adjust the flow rate
adjustment screw.
16| EN