I , .j \m – Инструкция по эксплуатации Beko CG 41010 G
Страница 41
Внимание! Текст в этом документе был распознан автоматически. Для просмотра оригинальной страницы Вы можете воспользоваться режимом "Оригинал".
By-pass adjustment of Thermostate
Open
the
oven
door.
To
dismount
the
fornt
panel
unscrew
the
'B'
screw.
Using
a
screwdriver
adjust
the
'A'
screw
as
shown
below.
For
the
appropriate
functioning
of
the
oven
re-checking
the
by-pass
adjustment
is
extremely
important.
In
order
to
prowide
maximum
security
to
the
user
these
operations
have to be done with care.
Adjust
the
oven
thermostat
setting
to
position
6(with
Tap
models position 3).
You will have to wait
15 minutes
until
to the oven that is stabilized.
When the thermostat setting is at position 1;
-
If
the
flame
extinguishes
loosen
the
A
screw
a
small
amount.
-
If the flames are longer than 2-3mm, fasten the A screw.
»
■I
, .J
\m
If the temperature of the oven increases extremely refer
to your service for the repairation of the thermostate.
18