End of season storage, Troubleshooting – Инструкция по эксплуатации Shivaki SHPC-0915E

Страница 12

Advertising
background image

10

END OF SEASON STORAGE

1. Screw off the drain cap, unplug the water plug and

drain the water in the water tray to another vessel
that holds water.
Note: the tilt angle of the unit shall not be greater than
30 degrees.

2. Start the unit, turn the mode to the low fan speed

state of the air supply mode, keep this for half a day
and dry the interior of the unit to prevent mold.

3. Turn off the unit, unplug the power plug, wrap the

power cord around the wire-winding post, insert the
plug into the universal jack at the back side of the
unit; install the water plug and drain cap.

4. Remove the heat exhaust hose assembly and keep it

properly.

Note: to remove the heat exhaust hose assembly,
hold the handle of the C shape buckle of the heat
exhaust hose by hand, pull the C shape buckle
outward evenly, rotate the C shape buckle of the heat
exhaust hose clockwise once the buckle is separated
from the snap position of the C shape buckle of the
back shell and then take out the heat exhaust hose
assembly.

5. Pack the air conditioner properly with soft plastic

bag, put the unit in a dry place & take appropriate
dust-proof measures, and keep the unit out of the
reach of children.

6. Take out the batteries of the remote control and keep

it properly.

Note: ensure that the unit is put in a dry place. All
accessories of me unit shall be protected properly.

TROUBLESHOOTING

Trouble

Solution

Unit does not operate

Is the unit plugged in?
Is the power outlet switched on?
Is the Full Water Indicator on? ((If so empty the condensed water).



Unit does not cool effectively

Is the room too large?

Is there direct sunlight onto the unit? (close curtains end pull down
blinds)
Are windows or doors open?
Is there another heat source in the room?
Is the filter dirty or contaminated?
Is the air intake blocked?
Is the outlet duct venting the hot air property?
Is the room temperature below your selected temperature?

Too Noisy

Is the unit positioned on an uneven hard floor surface creating
vibration?
Note: A soft carpeted surface may absorb vibrations.