Инструкция по эксплуатации Beko CS 61110

Страница 33

Внимание! Текст в этом документе был распознан автоматически. Для просмотра оригинальной страницы Вы можете воспользоваться режимом "Оригинал".

Advertising
background image

Part 2: Important Installation and preparation of your oven

Belpre your appliance is connected to the

mains electricity supply, check, to ensure that

the voltage and the trequency shown in the

data plate corresponds with your power supply.

The data plate is situated back cover of the oven,

or it is situated in the front of the storage

compartment and can be seen by opening the

storage compartment cover or pulling the drawer.

Warning!
This appliance must be earthed

Our company shall not held responsible for any

damage caused by the utilisation of the oven

without ground socket.
•• Before applying to Authorized service, have

the electrical wiring of your home ready for

connection.

If the appliances is connected by a plug, that

the plug is easily accessible after installation (but

not above the hob)

»■ This product must only be installed by a
qualified electrician eg. local electricity company

to a suitable double pole control unit with a

minimum contact clearance of 3 mm in all poles

which should be adjacent to (but not above) the

cooker in accordance with

iee

regulation. Failure

to observe this instruction may result in

operational problems and invalidation of the

product warranty. If the appliance is connected
by a plug, that the plug is easily accessible after

installation (but not above the hob).

The cable length should be 2 mt max for

isolation safety.

In models with "small type- terminal block"

In mix models a cable supplied with a plug with your

oven (H05 VV-F 3G 1.5 mm2)

If a cable without a plug is provided together

with your oven (H05 VV-F 3G 2,5 mm2 )

Take care to connect as below:

Brown cable = L (Live)

Blue cable = N (Neutral)

GreenA'ellow cable = E (Earth )

*■ If your oven is supplied without supply cord use

schema

-1

to choose supply cord and use schema-

11

for installation of cord.

The cable length should be max 2m long for isolation

safety.

•■ Open the terminal block cover.

•■ Connect the supply cable according to wiring diagram on the rear

cover.

•■ Fix the supply cable to main body with integrated screw via cable

tightener.

•■ Assembly the terminal block cover to its place.

Your oven is suitable for single and three phase connection.

•■ The mains cable must pass through the cable clamp.

•■ The mains cable should be routed away from the appliance and in particular

ventilation slots, the vent outlet and should not be obstructed when pushed

In to position between the appliance and the wall and/or cabinet.

АП

| 1

?идг: 3fCL'¿<ip.'4if;v

гВШООьЦЕ V

Schema //

1

© О

Connection Type

Monophase

Three phase

with Neutral

Two phase

with Neutral

Voltage

220/230/

240 V

380/400/41

5 V

380/400/

415 V

Supply cord type

(max

2

m long)

3x4.0 mm2

H05 VV-F

5x2,5 mm2

H05 V V-F

4x2,5 mm2

H05 V V-F

Advertising