1.2.2 BATTERY CABLE CONNECTION (ELECTRIC START

ONLY)

The unit has been deliberately shipped with the battery cables

disconnected. You will need a 10mm wrench to secure the battery

cables.
To connect the battery (see Figure 15 for connection details):

1. Cut off cable ties securing battery cables and remove red

covers from battery terminals.

2. First, connect the red cable to the positive (+) battery terminal

with the bolt, lock washer and nut supplied.

3. Connect the black cable to the negative (-) battery terminal

with the bolt, lock washer and nut supplied.

4. Make sure all connections are secure. Slide the rubber boots

over the terminals and connection hardware.

NOTE:

If the battery is unable to start the engine, charge it with the

12V charger included in the accessory box (see the "Charging a

Battery" section for details).

2.1 KNOW THE GENERATOR

Read the Owner’s Manual and Safety Rules before operating

this generator.
Compare the generator to Figures 2 through 4 to become

familiarized with the locations of various controls and adjustments.

Save this manual for future reference.

1. 230 Volt AC, 16 Amp, CEE 7/4, Type F Receptacle – Supplies

electrical power for the operation of 230 Volt AC, 16 Amp,

single-phase, 50 Hz electrical lighting, appliance, tool and

motor loads.

2. 230 Volt AC, 30 Amp Locking Receptacle – Supplies

electrical power for the operation of 230 Volt AC, 30 Amp,

single-phase, 50 Hz, electrical lighting, appliances, tools and

motor loads. To be used with supplied adapter cord.

3. Circuit Breakers (AC) – Each receptacle is provided with a

push-to-reset circuit breaker to protect the generator against

electrical overload.

4. Oil Drain – Use to drain engine oil.
5. Air Filter – Filters intake air as it is drawn into the engine.
6. Choke Knob – Used when starting a cold engine.
7. Fuel Tank – See generator Specifications for tank capacity.
8. Grounding Lug – Ground the generator to an approved earth

ground here. See "Grounding the Generator" for details.

9. Run/Stop Switch – Controls the operation of the generator

(pull start models).

9A. Start Switch – Used to start engine from the starter motor

(electric start models only).

10. Muffler – Quiets the engine.
11. Handle – Pivot and retract for storage. Press the spring-

loaded button to move handles (GP5000/GP6000 only).

12. Gas Cap – Fuel fill location.

13. Fuel Gauge – Shows fuel level in tank.
14. Oil Fill – Add oil here.
15. Recoil Starter – Use to start engine manually.
16. Fuel Shut Off – Valve between fuel tank and carburetor.
17. Battery Charger Input – This receptacle allows the capability

to recharge the 12 volt DC storage battery provided with

the 12 Volt Adaptor Plug Charger which is included in the

Accessory Box. Located behind the battery charger input is

a 1.50 Amp in-line fuse which is inside the control panel to

protect the battery (electric start models only).

18. Battery – Powers the electric starter (electric start models

only).

19. Hourmeter – Tracks hours of operation (GP5000/GP6000

only).

20. Spark Arrestor – Reduces fire hazards by containing sparks

(GP2600 only).

Figure 2A - Control Panel (GP5000)

Figure 2B - Control Panel (GP6000)

Operation