5 service air cleaner, 6 valve clearance, Maintenance – Инструкция по эксплуатации Generac GP6000E

Страница 18

Advertising
background image

16

Figure 16 - Spark Arrestor

3.5 SERVICE AIR CLEANER

3.5.1 GP5000/GP6000 AIR CLEANER

The engine will not run properly and may be damaged if using

a dirty air cleaner. Clean or replace the air cleaner paper filter

once a year. Clean or replace more often if operating under dusty

conditions (Figure 17). The air filter part number is 0G84420151.
To clean or replace paper air filter:

1. Remove air cleaner cover and remove paper filter.
2. Clean paper filter by tapping it gently on a solid surface. If the

filter is too dirty, replace it with a new one. Dispose of the old

filter properly.

3. Clean air cleaner cover, then insert new paper filter into the

base of the air cleaner. Re-install air cleaner cover.

Figure 17 - Air Filter (GP5000/GP6000)

3.5.2 GP2600 AIR CLEANER

The engine will not run properly and may be damaged if using a

dirty air filter. Clean the air filter every 25 hours (Figure 18). Clean

or replace more often if operating under dusty conditions.

1. Remove air filter cover.
2. Wash in soapy water. Squeeze filter dry in clean cloth (DO

NOT TWIST).

3. Clean air filter cover before re-installing it.

Figure 18 - Air Filter

AIR FILTER

COVER

AIR

FILTER

UNLOCK

COVER

MOVE TO

THE RIGHT

3.6 VALVE CLEARANCE

3.6.1 GP5000/GP6000 VALVE CLEARANCE

• Intake — 0.15 ± 0.02mm (cold)
• Exhaust — 0.20 ± 0.02mm (cold)
After the first 50 hours of operation, check the valve clearance

in the engine and adjust if necessary.
Important:
If feeling uncomfortable about doing this procedure or

the proper tools are not available, please take the generator to the

nearest service center to have the valve clearance adjusted. This is

a very important step to ensure longest life for the engine.

3.6.2 GP2600 VALVE CLEARANCE

• Intake — 0.10 ± 0.02mm (cold)
• Exhaust — 0.15 ± 0.02mm (cold)

After the first 50 hours of operation, check the valve clearance

in the engine and adjust if necessary.
Important:
If feeling uncomfortable about doing this procedure or

the proper tools are not available, please take the generator to the

nearest service center to have the valve clearance adjusted. This is

a very important step to ensure longest life for the engine.