2.2 HOURMETER (GP5000/GP6000 ONLY)

The Hourmeter tracks hours of operation for scheduled maintenance

(Figure 4):
There will be a "CHG OIL" message every 100 hours. The message

will flash one hour before and one hour after each 100 hour

interval, providing a two hour window to perform service.
This message will actually begin flashing at 99 hours and disable

itself at 101 hours again, providing a two hour window to perform

the service.
Every 200 hours the "SVC" icon on the lower left hand corner of

the display will flash. The message will flash one hour before and

one hour after each 200 hour interval providing a two hour window

to perform service.
When the hour meter is in the Flash Alert mode, the maintenance

message will always alternate with elapsed time in hours and

tenths. The hours will flash four times, then alternate with the

maintenance message four times until the meter resets itself.
• 100 hours - CHG OIL — Oil Change Interval (Every 100 hrs)
• 200 hours - SVC — Service Air Filter (Every 200 hrs)

NOTE:

The hour glass graphic will flash on and off when the engine

is running. This signifies that the meter is tracking hours of

operation.

Figure 4 – Hourmeter

HOUR GLASS
GRAPHIC

RESET BUTTON
(IF EQUIPPED)

0000.0

2.3 CORD SETS AND CONNECTION PLUGS

2.3.1 230 VAC, 16 AMP, CEE 7/4, TYPE F RECEPTACLE

This is a 230 Volt outlet (Figure 5) protected against overload by

a 16 Amp push-to-reset circuit breaker. Use each socket to power

230 Volt AC, single phase, 50 Hz electrical loads requiring up to a

combined 3,680 watts (3.6 kW) or 16 Amps of current. Use only

high quality, well-insulated, 3-wire grounded cord sets rated for

230 Volts at 16 Amps (or greater).
Keep extension cords as short as possible, preferably less than

5 meters long, to prevent voltage drop and possible overheating

of wires.

Operation