9
Figure 5 - 230 Volt AC, 16 Amp, CEE 7/4, Type F
Receptacle
2.3.2 230 VAC, 30 AMP RECEPTACLE (GP5000/GP6000
ONLY)
Use this receptacle (rotate to lock/unlock) to operate 230 Volt AC,
50 Hz, single phase loads requiring up to 5000 watts (5.0 kW)
or 6000 watts (6.0 kW), depending on the model. The outlet is
protected by one 30/25 Amp circuit breaker.
Figure 6 - 230 VAC, 30 Amp Receptacle
2.3.3 ADAPTPER CABLE, 50 HZ (GP5000/GP6000 ONLY)
Included with this generator is an adapter cable that plugs into the
30 Amp Twistlock receptacle on the generator control panel on one
end, and provides a 32 Amp IP44 CEE 2P+E socket on the other
end (Figure 7).
Figure 7 – Adapter Cable
2.4 HOW TO USE THE GENERATOR
To obtain contact information for the nearest authorized dealer, go
to www.generac.com/Dealer Locator.
Never operate in an enclosed area or indoors!
NEVER use in the home, in a vehicle, or in
partly enclosed areas such as garages, EVEN
IF doors and windows are open! ONLY use
outdoors and far from open windows, doors,
vents, and in an area that will not accumulate
deadly exhaust.
The engine exhaust fumes contain carbon
monoxide, which can you cannot see or smell.
This poisonous gas, if breathed in sufficient
concentrations, can cause unconsciousness or
even death.
Adequate, unobstructed flow of cooling and
ventilating air is critical to correct generator
operation. Do not alter the installation or permit
even partial blockage of ventilation provisions,
as this can seriously affect safe operation
of the generator. The generator MUST be
operated outdoors.
This exhaust system must be properly
maintained. Do nothing that might render the
exhaust system unsafe or in noncompliance
with any local codes and/or standards.
The manufacturer recommends installing
a battery operated carbon monoxide alarm
indoors, according to the manufacturers
instructions.
Operation