15
3.4.4 CHECKING OIL LEVEL
See the “Before Starting the Generator” section for information on
checking the oil level. The oil level should be checked before each
use, or at least every eight hours of operation. Keep the oil level
maintained.
3.4.5 CHANGING THE OIL
Change the oil after the first 20 to 30 hours of operation. Change
the oil every 50 to 100 hours or every season thereafter. If running
this unit under dirty or dusty conditions, or in extremely hot
weather, change the oil more often.
Hot oil may cause burns. Allow engine to
cool before draining oil. Avoid prolonged
or repeated skin exposure with used oil.
Thoroughly wash exposed areas with soap.
Use the following instructions to change the oil after the engine
cools down:
1. Clean area around oil drain plug.
2. Remove oil drain plug from engine and oil fill plug to drain oil
completely into a suitable container.
3. When oil has completely drained, install oil drain plug and
tighten securely.
4. Fill oil sump with recommended oil. (See “Before Starting the
Generator” for oil recommendations).
5. Wipe up any spilled oil.
6. Dispose of used oil at a proper collection center.
3.4.6 REPLACING THE SPARK PLUG
See Engine Specifications for recommended spark plug. Replace
the plug once each year. This will help the engine start easier and
run better.
1. Stop the engine and pull the spark plug wire off of the spark
plug.
2. Clean the area around the spark plug and remove it from the
cylinder head.
3. Set the spark plug's gap to 0.70-0.80 mm. Install the correctly
gapped spark plug into the cylinder head (Figure 14).
Figure 14 - Spark Plug Gap
3.4.7 BATTERY REPLACEMENT (IF APPLICABLE)
NOTE:
The battery shipped with the generator has been fully charged.
A battery may lose some of its charge when not in use for
prolonged periods of time. If the battery is unable to crank the
engine, plug in the 12V charger included in the accessory box
(see the Charging a Battery section). RUNNING THE GENERATOR
DOES NOT CHARGE THE BATTERY. The part number for this
battery is 0G9449.
The NEGATIVE battery terminal should:
1. Always be DISCONNECTED FIRST.
2. Always be CONNECTED LAST.
Figure 15 - Battery Connections
3.4.8 SPARK ARRESTOR
The engine exhaust muffler has a spark arrestor screen. Inspect
and clean the screen at least once each year (Figure 16). If unit is
used regularly, inspect and clean more often.
NOTICE:
If using the generator on any forest-covered, brush-covered
or grass-covered unimproved land, it must equipped with a
spark arrestor. The spark arrestor must be maintained in good
condition by the owner/operator.
Clean and inspect the spark arrestor as follows:
1. Remove clamp and spark arrestor from muffler.
2. Inspect screen and replace if torn, perforated or otherwise
damaged. DO NOT USE a defective screen. If screen is not
damaged, clean it with commercial solvent.
3. Replace the spark arrestor and clamp.