English – Инструкция по эксплуатации TIMBERK ICE.BEE series AC TIM 09HE P4

Страница 7

Advertising
background image

7

ENGLISH

NOTICE.
The unit can evaporate condensed water and automatically drain it
through the hose.
1. When the unit is in cooling mode, it is not necessary to install the
condensate drainage pipe since condensate evaporates automatically.
Make sure that when the unit is operating, the rubber plug of the
drainage hose is securely fixed (see Fig. 10).
2. In heating mode, remove the rubber plug (2) of the drainage hose
(Fig. 10), install the respective drainage hose to improve heating
efficiency.
3. In dehumidification mode, remove the rubber plug (2) of the
drainage hose, install the respective drainage hose.
Disconnect the air outlet hose, connect the drainage hose to the
drainage hole and drain water from the unit to ensure maximum
dehumidification efficiency.

E4 signal is shown on the LED display at the maximum water level (for

AC TIM 09HE P4). As for AC TIM 05H P4, AC TIM 07H P4 and AC TIM 09H
P4 FULL indicator is on in this case.
To resume the operation, remove the rubber plug (2) of the drainage
hose to drain water at first. After water is drained, turn the unit on, the
unit will resume operation

. 10

6.

Maintenance

IMPORTANT!
Disconnect the unit from the mains prior to cleaning.

1. When cleaning the air conditioner, do not use gasoline, solvents and other

chemically active substances.
2. To avoid electric shock and damage to electrical components, do not pour

water on the air conditioner from a tap or a hose.

Installation of the filter is performed in the reverse order.
Filter cleaning
At first, carefully clean the filters by means of vacuum cleaners. Then immerse

the filter in warm water (about 40°C) with a soft detergent, wash it and dry it

without exposure to direct sunlight.
Air intakes (heat exchangers)
Use a vacuum cleaner for cleaning.
Case
Wipe the surface by a damp cloth and dry it by a soft dry cloth.
Automatic condensate removal
Condensate is automatically removed from the unit. Moisture inside the unit

starts to evaporate and is removed from the unit through an air duct (or an air

diffuser) in the form of steam.

www.timberk.com electric floor standing air onditioner ortable type (single case)

ENGLISH

Fig. 11

3. Do not use the air conditioner if the power cord is damaged. On the subject

of replacing a damaged power cord, contact an authorized service center.
Air filter
Air filter clogging with dust particles impairs the air conditioner operation

efficiency, therefore clean the filter no less than once in two weeks.
Filter removal/installation
Remove the air filter in the direction, indicated by the arrow. Slightly push it

and then take it out from the device for cleaning. (See Fig. 11).

Fig. 10