Инструкция по эксплуатации Alinco DR-135 FX/E/T
Страница 45
12, Приложение
Команда
Короткая
форма
По
умолчанию
Параметры
Описание
FIRMRNR FIR
OFF
ON/OFF
The other station sends a notice (packet) to
you if it is not ready to receive data. When
ON, receiving such a notice c auses the TNC
to suspend transmission until it receives a
“ready” notice.
FLOW F ON
ON/OFF
When ON, starting key entry causes the
computer to stop displaying received pack-
ets.
FRACK FR 3
0
–
250
Specifies the interval from one transmission
until retry of transmission. The unit of the
parameter is 1 second.
GBAUD GB 4800
4800/9600
Selects 4800 or 9600 bps as the transfer
rate between the TNC and the GPS re-
ceiver.
GPSSEND GPSS -
0
–
1 59
characters
Specifies the content of the data to be output
to the GPS receiver; this data is used to
program the default settings on the receiver.
The output data is not stored in memory.
GPSTEXT
GPST
$PNTS
0 – 6 characters
Specifies the type of a message to be de-
termined by LTEXT.
HBAUD HB 1200
1200/9600
Selects 1200 or 9600 bps as the transfer
rate between pac ket stations.
LOCATION LOC
EVERY
0 EVERY/
AFTER n
( n = 0 - 250 )
If set to EVERY, sends GPS data at inter-
vals of the s pec ified period (n). If set to
AFTER, sends GPS data only once after the
specified period (n). The unit of n is 10 sec-
onds.
LPATH
LPA
GPS
Call1 ( VIA
call2, call3, ...
call9 )
Specifies calls signs to send GPS data. Call
1 is the call sign of the destination. Call2 to
call9 are call signs of stations to be
digipeated through.
LTEXT LT -
0
–
159
characters
Specifies the content of a message to be
included in GPS data.
LTMON LTM 0
0
–
2 50
Specifies the interval for displaying a mes-
sage determined by LTEXT on the screen; a
message appears like a received beacon
packet. The unit of the parameter is 1 sec-
ond.
MCOM MCOM
OFF
ON/OFF
When ON, c auses the TNC to also monitor
control packets . When OFF, causes it to
monitor only information pac kets.
MCON MC OFF
ON/OFF
When ON, c auses the TNC to monitor other
stations while in connection with the target
station.
MONITOR M
ON
ON/OFF
When ON, causes the TNC to monitor
packets.
MRPT MR ON
ON/OFF
When ON, c auses the TNC to display the
entire digipeat list for monitored pac kets.
MYCALL
MY
NOCALL
6 characters + SSID
Specifies your call sign.
PACLEN P
128
0
–
255
Specifies the maximum length of the data
portion of a pac ket.
PACTIME PACT AFTER
10 EVERY/
AFTER n
( n = 0~250 )
If set to EVERY, sends a packet at intervals
of the specified period (n). If set to AFTER,
sends a packet onl y once after the specified
period of (n). The unit of n is 100 millisec-
onds.
PERSIST PE
128
128
Specifies a parameter to c alculate probabil-
ity for the PERSIST/SLOTTIME method.
PPERSIST PP
ON
ON
Causes the TNC to use the PER-
SIST/SLOTTIME method when ON, or the
DWAIT method when OFF.
43