Part 9: Gas conversion

Your cooker can operate both

Natural Gas and LPG. You can
convert by changing the gas
source and the top burner, oven
and g r i l l I n j e c t o r s . T h e
replacement procedure of the
injectors are explained below.

Call authorized Service for gas
convertion.

Replacement of the

top burner injector

Take off the burner head and

burner cap before starting this
procedure. Then:
1. Remove the injector inside

the top burner with a suitable

bit. Later, install the new
injector by covering the injector

threads with leakage

preventing

material.

Flame failure

device

spark plug

Reduced Tap Flow

1.Ignite the burner that should be

adjusted, turn the knob to the reduced

position, pull and take the knob off.

2. With a screwdriver, make the tap

reduced flow adjustment from the
injector that is on the gas tap (only

the head is visible with the bolt shape).

It is sufficient to tight to screw

completely, in butane/propane gas.

For the natural gas, you should turn

the screw counter-clockwise once. The

normal length of a straight flame in

the reduced position should be 6 -

7mm.

If the flame is higher than the desired
position, turn the screw clockwise. If
its smaller to the opposite.
For the last control of the burning of

the cooker, bring the cooker high-
flame and reduced positions and check
whether the f l a m e i s o n o r o f f .