Cyborg start, Схемы подключения к центральному замку – Инструкция по эксплуатации Mongoose Cyborg Start

Страница 12

Advertising
background image

Two Way Car Alarm System MONGOOSE CYBORG START

5

ENGLISH

Start the engine using the ignition key and the alarm system will monitor the Engine RPM

signal.

When the engine has reached the idle speed, press button 3 within 3 seconds of pressing

button 5 to start the idle frequency learning.

The system will monitor the engine RPM signal for 3 seconds and save the average

frequency during this period as the idle frequency.

Once the RPM Signal has been learnt, the system will automatically exit learning mode

beeping the siren unit and flashing the indicators 3 times to indicate that the RPM signal
has been learnt. The system will return to the Installer Software Switch Table at
switch 2 7 RPM Learning (you can use the override switch to move up and down the
installer switches as normal)

Notes:

If the you tried to start the car during RPM learning mode and the engine does not start,

then the 1 minute learning timer will be reset when the starter motor is switched off.

If the system remains in learning mode for 1 minute without a (a further) attempt to start

the vehicle being made, the system will exit RPM learning mode, beep the siren and flash
the indicators 4 times and return to Installer Software Switch 2 7 RPM Learning.

If the system reads an engine RPM signal but is unable to learn the frequency of the signal,

the system will exit learning mode 1 minute after the engine was started and return to
Installer Software Switch 2 7 RPM Learning beeping the siren and flashing the indicators
5 times to indicate that the signal could not be learnt.

RPM Remote Start cannot be used unit an Idle Engine RPM signal has been taught to the

system – i.e. you must select Installer Software Switch 2 7 RPM Learning and complete the
procedure above with a 3 flash/3 beep confirmation being given by the system before Remote
Start will function.

After the RPM Leaning has been completed the Voltage sensing and the Generator/Oil

Lamp Sensing will be unavailable until the RPM Learning is canceled.

Canceling of the RPM Learning:

1. Select Installer Software Switch 2 7 RPM Learning.
2. Press buttons 1 and 2 together to enter the RPM learning mode and start the 1 minute

timer.

3. The siren will beep 3 times and the indicators will flash 3 times.
4. Press buttons 1 and 2 together once again.
5. The siren will beep 2 times.
6. The RPM Learning is now canceled and RPM sensing is unavailable. You can use either

the Voltage Sensing or the Generator/Oil Lamp Sensing.

Инструкция по установке

CYBORG START

24

СХЕМЫ ПОДКЛЮЧЕНИЯ К ЦЕНТРАЛЬНОМУ ЗАМКУ

Advertising