Tips for changing filters – Инструкция по эксплуатации Tefal PU4025

Страница 9

Advertising
background image

9

The pre-filter is the only filter which can be re-used and washed with water. The HEPA, NanoCaptur and
active carbon filters cannot be cleaned and re-used. Never wash with water.

To replace the filters, follow the instructions in the section “Disassembling/Reassembling filters” .

Your replacement filters are available under the following codes:

IMPORTANT: Resetting the filters
The reset light flashes when a filter needs to be replaced. Once the filter has been replaced, hold down the reset

button for 2 seconds.

.

Forced reset:
If you have replaced a filter before its end of life, force the reset of the filter replacement cycle:

1. Hold the reset button for 2 seconds.

.

2. Press the reset button briefly to select the filter you have changed.
3. After selecting the filter to reset, hold the reset button for 2 seconds. The electronic meter is then reset.
4. If no button is activated for 10 seconds in forced reset mode, the reset mode is canceled.

Pollution sensors

The particles sensor and gas sensor (model PU6025 only) need to be cleaned regularly (every 2 months) and
appropriately.
Make sure you turn off and unplug the appliance before cleaning the pollution sensors and follow the
recommendations below:

1. Clean the air inlet and outlet using a soft brush or cloth.
2. Open the sensor cover located on the right-hand side of the appliance.
3. Lightly wet a cotton swab and remove any dust from the lens and the inlet/outlet. Wipe using a dry cotton

swab.

4. Clean the gas sensor using a soft brush or vacuum cleaner.

IMPORTANT:
Never use a detergent or metal object to clean the sensors.
The efficiency of the sensors may be reduced if not cleaned regularly.
Cleaning frequency varies depending on the operating environment of the appliance. If it is used in a
dusty environment, clean the sensors more frequently.

« TIPS FOR CHANGING FILTERS »

.

Avoid handling used filters if you suffer from allergies or asthma.

.

Wear gloves when changing the filters, or wash your hands well afterwards.

.

Put used filters directly into a closed, air-tight bag before throwing them away to avoid
spreading pollutants.

1

2

3

4

Filter

Code PU4025

Code PU6025

HEPA filter

XD6070

XD6071

Active carbon filter

XD6060

XD6061

NanoCaptur filter

XD6080

XD6081

EN

903566-03-PU4025-PU6025.qxp_903566/03 25/06/15 16:58 Page9