5. IMPORTANT fACTORS, RULES AND

REGULATIONS

Kastor Chimneys have been designed for use only as a flue
channel for the flue gases emitted by fireplaces that are used
according to regulations. Emissions that differ from the regula-
tions (e.g. heat, pollutants) may damage the chimney. To
prevent damage to the flue channel, avoid burning plastics or
material that includes plastic (possible creation of hydrochlo-
ric acid, for instance). Various glues may also contain plastic
or other pollutants, which is why glued pieces must not be
burned in the fireplace.

Always check that the fireplace and its accessories are in a
condition that ensures clean flue gas. The condition of the
chimney must be checked regularly, i.e. once a month!

In addition to these instructions and official regulations, the
instructions given by the fireplace’s manufacturer must also
be heeded, as well as the limits set by the output of fireplaces
to various types of chimneys. The temperature of flue gases as
they exit the fireplace must not exceed 600°C/1112°F for more
than short periods. Sauna stoves can at times produce flue
gases that are this hot.

It must also be noted that according to building codes), chim-
neys must not have extensive horizontal draughts without
assurance of a good draft for instance with a roof exhaust van.
The matters presented in these instructions are valid only for
parts manufactured by Kastor Oy. Kastor Oy does not take
responsibility for cases in which parts from other manufactur-
ers were attached to our systems.

If anything is unclear, we urge you to inquire about them from
your local fire inspector or the manufacturer. According to of-
ficial regulations chimney fires, even extinguished ones, must
always be reported to the fire department.

The chimney must be inspected after every chimney fire due
to the high temperatures it causes.

Warning: Neglecting these instructions or official regulations
may lead to damage in the chimney and fires or other hazard-
ous situations.

5.1. WARRANTY

Kastor products are of high quality and reliability. Kastor
grants a warranty of 10 years for manufacturing defects on its
Chimneys. The warranty does not extend to damage caused by
incorrect use or disregard of these instructions. See chapter 3.

5.2. TECHNICAL DATA

The Kastor Chimney has been CE certified according to the
requirements for metal chimneys in SS-EN 1856-1:

Certificate CE 0036 CDP 90286 001
KASTOR CHIMNEY -
EN 1856-1 T600 N1 D V3 L50060 G50
EN 1856-1 T600 N1 W V2 L50060 O50

EN 1856-1 product standard
T600

temperature class

N1

pressure class

D/W

condensation class

V3/V2

corrosion class

L50060 material class
G50

chimney fire class, safety distance to flammable

structures

T600 Temperature class: The temperature of flue gases in the
chimney may not exceed 700°C/1292°F.

D/W usage classes: The Kastor KC has been certified for the
flue gases of both dry (D, wood and pellet operated) and wet
(W, gas and thin oil operated) fireplaces and furnaces.

L50060 Material type and thickness: Stainless, acid-proof
steel, 1 mm.

G Chimney fire class: The Kastor KC does withstand chimney
fires.

The safety distance to flammable structures: 50 mm.