1. Before installation

Inspect both product and the contents of the package as soon as you receive them. Report any

transport damages immediately to the deliverer. The fireplace's identification plate is at the bottom of

the back wall.

1.1. Package contents and its inspection

The fireplace package contains:

Fireplace

Within the fire compartment

Installation instructions

Grate

Rear flue opening plug, cover plate and attachment pipe

1.2. Transport and moving

For ease of transport and handling the fireplace is delivered in assembled form. See instruction 2.1.

The soapstone cladding must be removed before the fireplace is removed from its transport platform.

To avoid transport damage, the fireplace must be transported in upright position at all times.

Before any use, all decals and packaging must be removed. The identification plate must not be

removed.

1.3. Important matters and regulations

In addition to these instructions, all local ordinances and EU standards must be followed during

installation and use of this device. Make sure to find out about any building permissions you might

need and the carrying capacity of the floor before you start installing.

Prior to installation of the chimney or first use of the fireplace, the chimney's temperature

classification must be checked.

Median temperature of flue gas at nominal output is 304°C/580°F.

Required temperature classification of pipe is 400°C/752°F.

If the fireplace is attached to a shared chimney, the connection pipe must always have its own damper

plate.

Always check that the flue channel has sufficient draught before starting the fire.

At nominal output, the minimum draught pressure is -12Pa and the mass flow rate 6,4g/s.

This can be checked roughly by first burning some newspaper in the fireplace.

To avoid smoke escaping into the room during lighting and burning proceed as follows:

Shut off all devices that cause under pressure in the room such as a range hood or

mechanical ventilation.

If the ventilation system has been equipped with a fireplace switch, use it according to its

instructions.

If the fireplace has its own external air feed, make sure it is open, unimpeded and providing

good air flow.

Melody fireplaces are meant for heating rooms. They must not be used for any other purpose.

The fireplace is not designed for continuous use around the clock.

No decorative or other objects are to be placed on the fireplace and it must not be covered in

any way while it is hot or being heated.

To ensure optimal power and safety, the feeding door must be closed during heating. The

door may be left open during heating only, if the fireplace is under constant supervision. The

doors and glass surfaces must be treated with great care.

If the fireplace has been standing unused in a humid environment for a longish period (e.g. in

an unheated summer cottage), it must be inspected before use to make sure it does not have

corrosion damage and that the chimney is not blocked by a bird's nest or some such.