7.0 Trouble shooting guide

EN

To avoid unnecessary disappointments, you should check the following before contacting the ALTO service
organization:

Symptom Cause

Recommended

action

Machine refuses to start

Machine not plugged in

Plug in machine.

Defective socket

Try another socket.

Fuse has blown

Replace fuse. Switch off other machines.

Defective extension cable

Try without the extension cable.

Fluctuating pressure

Pump sucking air

Check that hoses and connections are air-

tight.
Valves dirty, worn out Clean and replace or refer to local ALTO
or stuck distributor
Pump seals worn out Clean and replace or refer to local ALTO
distributor.

Motor busses

Low voltage or

Activate the trigger of the spray gun.

low

temperature

Machine stops

Fuse has blown

Replace fuse. Switch off other machines.

Incorrect mains voltage Check that the mains voltage corresponds
to specifi cation on the model tag.

Thermal sensor activated

Leave the washer for 5 minutes to cool down.

Nozzle partially blocked

Clean the nozzle (see section 4.1)

Fuse blows

Fuse too small

Change to an installation higher than the

amp. consumption of the machine.

You may try without the extension cable.

Machine pulsating Air in inlet hose/pump Allow machine to run with open trigger until
regular working pressure resumes.
Inadequate supply of Check that the water supply corresponds to
mains water specifi cations required (see model tag)

NB! Avoid using long, thin hoses (min. 1/2”)

Nozzle partially blocked

Clean the nozzle (see section 4.1)

Water fi lter blocked

Clean the fi lter (see section 4.2)

Hose kinked

Straighten out hose.

Machine often starts

Pump/spray gun is

Contact your nearest ALTO Service Centre.

and stops by itself

leaking

Machine starts, but

Pump/hoses or accessory

Wait for pump/hoses or accessory to thaw.

no water comes out frozen

No water supply

Connect inlet water.

Water fi lter blocked

Clean the fi lter (see section 4.2)

Nozzle blocked

Clean the nozzle (see section 4.1)

In case problems other than the above occur, please contact your local ALTO distributor.
Customer services (UK only):

ALTO Cleaning Systems Ltd.

Phone: 01 768 868 995

Gilwilly

Industrial

Estate

Penrith,

Cumbria

CA11

9BN

Customer service (AUS):

ALTO Overseas Inc.

Phone: 02 9524 6122

1B/8

Resolution

Drive

P.O.

Box

797

Caringbah,

N.S.W.

2229

Advertising
Эта инструкция подходит к следующим моделям: