21. It is prohibited to install and use the appliance in bathrooms, showers, or

near swimming pools, where water jets and drops may directly get onto the

appliance surface, when it is switched on.
22. Do not switch the heater on, if its power cord or plug has damages. To

avoid risk of electric shock, the damaged power cord should be replaced

only in the manufacturer's authorized service centers by qualified specialists

(for TGH 4200 O2 model).
23. Never try to repair the heater yourself. This may inflict harm to your

health and affect the warranty service of the appliance.
24. Do not use the heater in open spaces outdoors for a long time.
25. Do not lay the heater power cord under carpets and do not press it with

furniture. Lay the power cord so that nobody can stumble over it.
26. Do not insert fingers and exclude penetration of foreign objects to any

vents, air intakes, or outlets, since this may result in burn, electric shock (for

TGH 4200 O2 model), other injuries, or damage of the heater.
27. To prevent possible fire, do not block the air intakes and outlets anyhow.

Do not hang or dry things on the heater! Use the heater only on even dry

surface.
28. The heater works with open flame and contains hot/sparking

components inside. Do not use the heater in places of handling or storage of

gasoline, paint, or any other flammable liquids.
29. Use the heater only as described in this Manual. Any other use not

recommended by the manufacturer may lead to fire, electric shock, or

injuries of people.
30. Never clean the heater, when it works. Do not submerge the heater into

water.
31. It's strictly forbidden to clean gas heaters, when it connects to power

supply and/or switches on. If you use model TGH 4200 O2, please, always

remember, it's forbidden to pull power cord by hands, especially during

device's operating.
32. To avoid overheating and risk of fire occurrence, as well as damage of the

internal electric circuit, do not change the power cord length and do not

connect the appliance via electric extension cords. However, if necessary,

you can use an extension cord, if its parameters meet the appliance power

and if it is not used by other consumers of electric power (for TGH 4200 O2

model).
33. For normal operation of the appliance, the mains voltage should be

sufficient and the mains specifications should strictly correspond to the

technical parameters indicated on the appliance body. If necessary, clarify

the specifications of your mains from the electricity supplier (for TGH 4200

O2 model).
34. Technical characteristics of gas, which will be used for Timberk gas

heaters must be absolutely the same, as rating labels & instruction manual

contain. It's important

35. It is prohibited to install the appliance immediately under an electric

socket or under a wired electric cable, when the output heat flows get to

them. This may result in their overheating causing an emergency situation.
36. Using TGH 4200 O2 model, please, do not switch on gas ceramic heater

and quartz heating tubes at the same time. It's forbidden at all
37. Install and operate the appliance in strictly vertical position. It is

prohibited to operate the appliance in horizontal or inclined positions.38.

The appliance is not designed for use by people (including children) with

limited physical, sensory, or mental capabilities and having insufficient

experience/knowledge, if they are not supervised and instructed on use of

the device by a person responsible for their safety. It is necessary to watch

that children do not play with the heater.

3. Working parameters
Operation principle
Gas is fed via a custom-made nozzle to small ceramic burner cells, where it is

ignited. As a result, the burner ceramic parts incandesce up to high

temperatures with simultaneous air heating via immediate open flame and

heating of surrounding objects via thermal (infrared) radiation from hot

ceramic parts.
Main features

1. Combination of thermal radiation and heat generation via open gas

.

combustion makes the heater a cost-effective source of thermal power.
2. Quick self-repayment thanks to high efficiency and speed of reaching set

temperature.
3. Simplicity of installation, reliability in operation, and easiness of

.

maintenance.
4. Simple and effective capabilities of temperature control and gas saving

thanks to three-mode selection of heating power - a burner with gradual start

and three power levels.
5. Piezo-ignition of flame.
6. Gas shutoff upon flame-out - an integrated flame detector.
7. Integrated three-mode quartz electric heater (in TGH 4200 O2 model).
8. The ODS protection circuit (oxygen detector) switches the heater off, if

oxygen content in air decreases to 18%.
9. The integrated tipping sensor switches the heater off, if it is inclined from the

vertical position, for example, if the appliance is accidentally overturned or

inclined.
10. Wheel base for movement of the appliance and for installation of the

heater in any convenient place.
11. Integrated handle for movement.
12. Gas reducer and 60cm hose are enclosed.
13. Internal clamp for a gas cylinder.

14

www.timberk.com

3

www.timberk.com gas heater

ENGLISH

2.

,

(

).

,

.

3.

, . .

.

(

TGH 4200 O2),

,

.

4.

, . .

.

, . .

.

5.

.

.

9.

10.

,

,

.

.

њֿ ׂ חו ז ֹ ּ דהחטע

Вероятная причина

Способ устранения

Неисправен пъезоэлемент

Обратитесь в авторизованный
сервисный центр

Не подсоединёны электрические
провода к пъезоэлементу

Подсоедините электрические провода к
пъезоэлементу

Повреждены электрические
провода пъезоэлемента

Обратитесь в авторизованный
сервисный центр

Неправильное положение
электрода пъезоэлемента по
отношению к запальной горелке

Отрегулируйте положение электрода по
отношению к запальной горелке так,
чтобы искра пробегала вдоль потока
газа и не попадала на корпус или
решётку прибора

Отсоединён провод термопары от
газового клапана

Подсоедините провод термопары к
газовому клапану

Неправильное положение датчика
термопары по отношению к
запальной горелке

Отрегулируйте положение датчика
термопары по отношению к запальной
горелке так, чтобы он находился в огне

Неисправен датчик падения

Обратитесь в авторизованный
сервисный центр

Используется газ низкого
качества

Используйте качественный газ

Неисправен редуктор - слишком
высокое или низкое давления газа

Обратитесь в авторизованный
сервисный центр

Сильное пламя на
керамической горелке

Неисправен редуктор - слишком
высокое давления газа

Обратитесь в авторизованный
сервисный центр

Не зажигается запальная
горелка

Запальная горелка горит
равномерно, но гаснет при
отпускании ручки регулировки
газа

Запальная горелка горит
неравномерно, пламя
отрывается от основания и
гаснет при отпускании ручки
регулировки газа