Cyborg – Инструкция по эксплуатации Mongoose Cyborg

Страница 13

Advertising
background image

User’s Guide

CYBORG

20

The following PIN code procedure should be used to exit the Anti Hi Jack:

Grace and Warning Periods with the ignition on:

a) Press the override switch the number of times equal to units’ digit of the PIN code.
b) Wait 3 seconds to ensure the override switch is not pressed again.
c) If the code is correct exit Anti Hi jacking mode and if it is not, continue with the Grace

(or Warning) period. Entering an incorrect code will not effect the 30 second Grace (or
Warning) period.

d) If an incorrect PIN code is entered twice in succession, then the PIN code procedure

will be blocked for 2 minutes. If you press the wrong transmitter button twice the transmitter
operation will also be blocked for 2 minutes.

During Anti Hi Jacking procedure (after Warning period):
a) Turn the ignition off to stop the siren unit and enable the immobiliser
b) Turn the ignition back on
c) Press the override switch the number of times equal to tens digit of the PIN code.
d) Cycle the ignition off/on.
e) Press the override switch the number of times equal to units’ digit of the PIN code.
f) Switch the ignition off.
e) If the PIN code is correct exit Anti Hi jacking mode.
f) If an incorrect PIN code is entered twice in succession, then the PIN code procedure

should be blocked for 2 minutes.

General Notes on all Hi Jacking Mode

1. If you switch the ignition off when the Anti Hi jack has already been activated there will

be a siren beep to indicate the alarm system cannot be armed from transmitter.

2. Once the PIN code has been entered, the system will go to the disarm condition.

3. During the entire Anti Hi Jacking procedure, the immobiliser will enable according to

the Blocking in Trouble Simulation function. However if the Permanent Block were
selected, the system would only go to permanent block when the ignition is switched
from ON to OFF. If blocking in trouble simulation is selected, the last 2 cycles of the
procedure i.e. 1 sec block and 2 second pause will repeat until the ignition is switched off
and then the immobiliser will enter permanent block mode.

Once the Anti Hi Jacking mode has been started, all transmitter operations with exception

of Passive Immobiliser disarm command will be completely ignored until the Anti Hi jack has
been exited.

Blocking in Trouble Simulation

(While in the Anti Hi jack)

This feature can be selected using programming.

The system includes an Installer’s function termed Blocking in Trouble Simulation. If the

function is OFF (Default setting) then the internal immobiliser will enable as normal i.e. as soon
as the ignition is switched off, the immobiliser relay will open and immobilise the vehicle. If the

Автомобильная охранная система “MONGOOSE” Модель CYBORG

41

РУССКИЙ

При срабатывании предупредительной зоны датчика удара или внешней зоны допол

нительного датчика, прозвучит короткая трель сирены.

Примечание: При срабатывании предупредительной зоны датчика сигнализация не

находится в режиме тревоги, поэтому при отключении индикации на пульте управления
кнопкой 1 Вы одновременно отключите предупредительную зону датчика, а при отклю
чении индикации кнопкой 2 – снимите сигнализацию с охраны. Если Вы хотите сохра
нить режим охраны и не хотите отключать предупредительную зону датчика, пользуй
тесь другими кнопками.

Индикацию срабатывания предупредительной зоны пультом управления Вы можете

отключить программно (функция 2 6 в таблице пользовательского программирования).

О включении тревоги пульт управления сообщит индивидуальной для каждой зоны охра

ны мелодией и/или включением виброзвонка. На дисплее пульта включится подсветка, и
замигает пиктограмма зоны вызвавшей включение тревоги.

Advertising