Инструкция по эксплуатации Saturn ST-CC0229
Страница 4
6
3. Switch out Cage Knob. Lift the rod
to proper height and then close Cage
Knob.
4. Cut Fixed Tube of Steam Hose into
Fixed Stopper of Steam Hose, and
then fix it. Re. fig.
5. Place the hose head on hanger.
6. Twist off the cap of the water tank,
then put water into the water tank.
7. Screw the cap, then put the water
tank into the unit.
8. Plug in and turn the switch to the
“1” gear, then the indicator lights up
and small steam will throw out; turn
the switch to the “2” gear and big
steam will throw out. When you finish
using, turn the switch to the “0” gear,
remove the plug and store the unit.
Damaged Checking & Reason
PHENOME
NA
CAUSE
RESOLUTI
ON
No working Electro-
circuit
breakdown;
Plug
disconnectio
n;
No light of
switch;
Fuse burned
Take it to a
qualified
service
person for
examination
and repair.
Big
noise
from
the
hose
and
low steam
Steaming in
low position
Straighten
hose up and
left
condensatio
n is free to
flow
back
into
steamer.
7
The water
drips from
the steam
head
The steam
head
damaged;
Steaming
not in an
upright
position
Exchange a
new steam
head
Straighten
hose up.
Water and
steam drips
from hose
connecting
position
Seal-ring
damaged;
No tight of
hose
connecting
position
Exchange a
new
seal-
ring
Screw
tightly
of
connecting
position
Water flow
out
from
the
water
tank
Water tank
broken
or
has hole
Exchange a
new water
tank
Water
in
water tank
became hot
Copper
water pipe
was
stopped up
Clean
up
the deposits
Low steam
than usual
Low
pressure
voltage;
Water tube
had
been
shut-up
Set
up
manostat
Remove
water
deposits
with
fresh
water
or
liquid
cleaner
Water tank
deformed
Infuse over-
hot water or
some
chemical
agent
Maintain
using
the
tank
Exchange
new water
tank
No
steam
but lamp is
light
Steam
generator is
broken;
Some
electronic
component
is broken
Take it to a
qualified
service
person for
examination
and repair
No steam
Steam
condensed
in
steam
pipe
Lift
the
brush head
and steam
pipe,
so
that
condensed
water
can
come
into
the
water
tank
Irregular
Steam
Steam
condensed
in
steam
pipe
and
brush head
Lift
the
brush head
and steam
pipe,
so
that
condensed
water
can
come
into
the
water
tank
Water drop
from brush
head
Steam
condensed
in
steam
pipe
Lift
the
brush head
and steam
pipe,
so
that
condensed
water
can
come
into
the
water
tank
Indicator
light off
Not plug in
or
power
switch is in
off position
Put the plug
in or press
switch
Indicator
light keeps
on
No water in
water tank
Auto
constant
temperatur
e knob is off
The cap of
water tank
not pressed
tightly
Fill
water
into
the
water tank
Adjust auto
constant
temperature
knob
clockwise
Tighten the
cap of water
tank
Smelled
steam
New
machine
Dirty inside
of
water
tank
Remove the
cap of water
tank
and
put
the
water tank
in
shadow
12 hours
Clean
the
water tank
by
clean
water
Indicator
light
on,
but no wind
no fog
Water
too
much than
water level
Pour some
water out
Humidifier
steam
lower than
usual
Transducer
scaling
Dirty water
or
water
stored too
long
Clean
the
transducer
Change the
water
in
water tank
Humidifier
steam
Check if the
appliance
Change the
machine