Приложение i, Rs-232c protocol, Rs-232c – Инструкция по эксплуатации Vivitek D7xx series

Страница 62: Rotocol, Риложение

Advertising
background image

Проектор DLP—Руководство для пользователя

– 54 –

П

РИЛОЖЕНИЕ

I

RS-232C Protocol

Note: Not all functions are available for all models due to different series.

RS232 Setting

Baud rate:

9600

Parity
check:

None

Data bit:

8

Stop bit:

1

Flow
Control

None

Minimum delay for next command: 1ms

Control Command Structure

The command is structured by the Header code, command code, data
code and end code. Most of the commands are structured except some
for the compatibility issue with other projectors.

Header code

Command code Data code

End code

HEX 7Eh

Command Data

0Dh

ASCII ‘~’

Command

Data

CR

Control Sequence

The projector may send a return code after it received a command. If the command isn’t
received correctly, the projector will not send the return code

Operation Command

The operation commands execute the basic operation setting of this projector.

Operation

ASCII

HEX

Power On

~ P N CR

7Eh 50h 4Eh 0Dh

Power Off

~ P F CR

7Eh 50h 46h 0Dh

Auto Image

~ A I CR

7Eh 41h 49h 0Dh

Lamp Hour Reset

~ R L CR

7Eh 52h 4Ch 0Dh

Input Select RGB

~ S R CR

7Eh 53h 52h 0Dh

Input Select RGB2

~ S G CR

7Eh 53h 47h 0Dh

Input Select DVI

~ S D CR

7Eh 53h 44h 0Dh

Input Select Video

~ S V CR

7Eh 53h 56h 0Dh

Input Select S-Video

~ S S CR

7Eh 53h 53h 0Dh

Input Select Component

~ S Y CR

7Eh 53h 59h 0Dh

Input Select HDMI

~ S H CR

7Eh 53h 48h 0Dh

Input Select Wireless

~ S W CR

7Eh 53h 57h 0Dh

Power On command will only word at system standby.

CR : Carriage Return.

Advertising