•The system should only be used with healthy pets who are over 6 months of age. Contact your veterinarian if you have concerns about the

medical condition of your pet (medication, pregnant, heart conditions, etc.).

•The PetSafe

®

Stubborn Dog In-Ground Fence™ is for residential use only.

•The Static Stimulation will get your pet’s attention, but will not cause harm. It is designed to startle, not to punish.
•Test the Receiver Collar at least once a month to verify that it is functioning properly. Check that it activates at the Boundary Wire. Battery life

depends upon how often the Receiver Collar is activated.

•Remove the Receiver Collar from your pet when indoors for the comfort of your pet.

Never leave the Receiver Collar on your pet for more than 12 consecutive hours.

short loop Test

The Short Loop Test is a simple test to determine if each component (Fence Transmitter, Receiver Collar and Boundary Wire) is functioning properly.
1. Disconnect the Boundary Wire.
2. Cut approximately 3 m of unused Boundary Wire and connect it to the Boundary Wire Terminals.
3. Spread the Boundary Wire out into a circle. Set the Boundary Control Switch to

B.

4. Set the Boundary Width Control knob to 10.
5. If the Loop Indicator Light is not lit, then your Fence Transmitter is not functioning properly. Contact the Customer Care Centre.
6. If the Loop Indicator Light is lit, disconnect one end of the Boundary Wire from the Boundary Wire Terminal.
7. If the loop alarm does not sound, the Fence Transmitter needs to be replaced. Contact the Customer Care Centre.
8. If the loop alarm does sound, plug the Boundary Wire back into the Boundary Wire Terminal.
9. Hold the Test Light Contacts to the Receiver Contact Points. Hold the Receiver Collar next to the 3 m length of Boundary Wire. The Receiver

Collar should beep about one foot away from the Boundary Wire. The Test Light should then flash as you hold the Receiver Collar closer to the
Boundary Wire.

10. If Receiver Collar does not beep and the Test Light does not flash, replace the battery in the Receiver Collar. If it still does not beep and the

Test Light does not flash, contact the Customer Care Centre.

11. If the Receiver Collar beeps, there may be a complete or partial break in the Boundary Wire. See the “To Locate a Break in the

Boundary Wire” section.