Using the instrument for the first time, Activating the fitted batteries, Setting the date and time – Инструкция по эксплуатации Microlife BP W100

Страница 6

Advertising
background image

4

The higher value is the one that determines the evaluation. Example:

a readout value between 150/85 or 120/98 mmHg indicates «blood

pressure too high».

2. Using the Instrument for the First Time

Activating the fitted batteries

Pull out the protective strip from the battery compartment 3.
Setting the date and time

1. After the new batteries are fitted, the year number flashes in the

display. You can set the year by pressing the M-button 5. To

confirm and then set the month, press the time button 6.

2. Press the M-button to set the month. Press the time button to

confirm and then set the day.

3. Follow the instructions above to set the day, hour and minutes.

4. Once you have set the minutes and pressed the time button, the

date and time are set and the time is displayed.

5. If you want to change the date and time, press and hold the time

button down for approx. 3 seconds until the year number starts to

flash. Now you can enter the new values as described above.

3. Taking a Blood Pressure Measurement using this

Instrument

Checklist for taking a reliable measurement

1. Avoid activity, eating or smoking immediately before the measurement.

2. Sit down for at least 5 minutes before the measurement and relax.

3. Always take the measurement on the left arm while in a sitting position.

4. Remove any items of clothing and your watch, for example, so that

your wrist is free.

5. Always ensure that the cuff is positioned correctly, as shown in the

pictures illustrated on the short instruction card.

6. Fit the cuff comfortably but not too tight. The cuff will cover a wrist

diameter of 13.5 to 21.5 cm (5.25 - 8.5 inches).

7. Support your arm in a relaxed position and ensure that the instru-

ment is at the same height as your heart.

8. Press the ON/OFF button 1 to start the measurement.

9. The cuff will now pump up automatically. Relax, do not move and

do not tense your arm muscles until the measurement result is

displayed. Breathe normally and do not talk.

10.When the correct pressure is reached, the pumping stops and the

pressure falls gradually. If the required pressure was not reached,

the instrument will automatically pump some more air into the cuff.

11.During the measurement, the heart symbol AN flashes in the

display and a beep sounds every time a heartbeat is detected.

12.The result, comprising the systolic 7 and the diastolic 8 blood

pressure and the pulse 9 is displayed and longer beep is heard.

Note also the explanations on further displays in this booklet.

13.Remove and switch off the monitor and enter the result in the

enclosed blood pressure pass. (The monitor does switch off auto-

matically after approx. 1 min.).

Advertising