Technical data, For the customer – Инструкция по эксплуатации Bosch Tronic 2000

Страница 18

Внимание! Текст в этом документе был распознан автоматически. Для просмотра оригинальной страницы Вы можете воспользоваться режимом "Оригинал".

Advertising
background image

Technical data

Model

ED5-2S/U

ED6-2S

Model

Pressurised (closed) / depressurised (open)

Weight Kg

1.8

1.8

Dimensions mm

250x144x100

Operating mode

Oontinuous

Mains connection

Permanent electrical connection

Nominal voltage

220 - 240 V

Nominal power kW / 230 V

4.6

6

Olass of protection in accordance with

lEO 335-1

1

I

Olass of protection in accordance with lEO 529

IP 24 (splash-proof)

Euse protection A

20

32

Erequency

50

50

Eittings connection Inches

3/8

1/2

Minimum flow pressure

0.1 M Pa (1 bar)

Maximum flow pressure

1 M Pa (10 bar)

Water volume at switch-on

approx. l/min

1.8

2.3

Water volume at switch-off

approx. l/min

1.4

1.8

Typical warm water output

at 37 °O l/min

2.5

3.0

After installation, give the user the operating instructions and explain how the appliance

works.

For the customer

Operation

Flow-through water heaters in this product series work automatically.

To switch on:

Open the tap fully. The flow-through water heater switches on and the

ON indicator (only on the ED6-2S) lights up. The water is heated as it flows through the
appliance.

To switch off:

Olose the tap, the appliance switches off.

To regulate the water temperature:

Open the tap fully, the appliance switches on.

Now increase the temperature by reducing the water flow volume.

Advertising