Technical data, For the customer – Инструкция по эксплуатации Bosch Tronic 2000
Страница 18
Внимание! Текст в этом документе был распознан автоматически. Для просмотра оригинальной страницы Вы можете воспользоваться режимом "Оригинал".
Technical data
Model
ED5-2S/U
ED6-2S
Model
Pressurised (closed) / depressurised (open)
Weight Kg
1.8
1.8
Dimensions mm
250x144x100
Operating mode
Oontinuous
Mains connection
Permanent electrical connection
Nominal voltage
220 - 240 V
Nominal power kW / 230 V
4.6
6
Olass of protection in accordance with
lEO 335-1
1
I
Olass of protection in accordance with lEO 529
IP 24 (splash-proof)
Euse protection A
20
32
Erequency
50
50
Eittings connection Inches
3/8
1/2
Minimum flow pressure
0.1 M Pa (1 bar)
Maximum flow pressure
1 M Pa (10 bar)
Water volume at switch-on
approx. l/min
1.8
2.3
Water volume at switch-off
approx. l/min
1.4
1.8
Typical warm water output
at 37 °O l/min
2.5
3.0
After installation, give the user the operating instructions and explain how the appliance
works.
For the customer
Operation
Flow-through water heaters in this product series work automatically.
•
To switch on:
Open the tap fully. The flow-through water heater switches on and the
ON indicator (only on the ED6-2S) lights up. The water is heated as it flows through the
appliance.
•
To switch off:
Olose the tap, the appliance switches off.
•
To regulate the water temperature:
Open the tap fully, the appliance switches on.
Now increase the temperature by reducing the water flow volume.