screws (A) fixed on the top cover, pull it forward and outwards.
Unscrew and remove the two nuts (B), remove the polystyrene then
replace the cover (C).
N.B. It is advisable to keep the packaging and transport holding
pieces in case the machine has to be transported again.
3. Positioning
Install the machine on a firm, flat surface. Make sure that nothing
– carpets, cloths etc., can prevent the air from circulating around
the machine. Make sure that the machine is not touching a wall or
any piece of furniture as this would cause vibrations.
Level the machine by screwing the adjustable feet up or down; nev-
er place a piece of wood or any other object underneath to set off
any difference in height between one side and the other. Once the
machine is level, tighten the counter nuts on the feet.
4. Connecting to the water supply
The appliance may only be connected to the cold tap. Screw one
end of the cold water intake hose to the threaded connection point
at the back of the appliance and connect the other to the cold water
tap. The machine is designed to work with a water pressure of 0.5
to 10 bar. Check that the connections are watertight.
5. Emptying the water
The machine uses a pump to empty the water. The end of the flex-
ible hose must be hung at a maximum height of 1 metre and mini-
mum 0.5 metres so the water can run off properly. Make sure there
are no kinks or snags in the runoff hose.
6. Electric connection
The machine is designed for use with 230V 50Hz. Connect the
machine to an earthed socket that complies with approved safety
standards. The makers refuse all responsibility in the event of dam-
age caused by failure to respect the security provisions.