then remove the filter also by turning it counterclockwise. The new filter is

installed in the reverse order. To purchase an ion exchange filter, please,
contact the seller.

Important!

Useful capacity of an ion exchange filter is about 400 liters. Continuous

use after expiration reduces the capability to filter hard components
(calcium and magnesium) of tap water. As a result, the level of white
residue formation increases.
Standard filter replacement period is about 180 days given the
automatic operation mode (duration of humidification with heating -
about 6 hours every day). Filter replacement period can be decreased
depending on different frequency of operation and water quality. Pay
attention to the formation of a white powder.

8. Cleaning and maintenance of the unit

Prior to cleaning make sure that the plug is disconnected from an outlet.

Otherwise it may result in an electric shock.

Before cleaning, wait until water in grooves is completely cooled down In

order not to burn hands.

8.1 To wipe the external surface of the unit use a damp and soft cloth.
To prevent an electric shock do not scratch and do not damage unit's
elements upon cleaning.
When cleaning the unit, do not use solvents, benzine, dimethylbenzene, hard

brush, talc powder and other substances other than water.

8.2 Wipe water remains inside the groove under the tank by a damp and soft

cloth.

To remove water remains on small parts you can use the brush, and then wipe
them again with a soft cloth. Clean the unit once or twice a week.
8.3 If there is dirt on the membrane, clean it by means of a brush. Clean the

unit once or twice a week.

www.timberk.nj • ultrasonic humidifier

8.4 Use a brush to remove water remains on the surface of the nozzle
and then wipe it again by a soft cloth. Clean the unit once or twice a
week.
8.5 Clean the water tank and the atomizer by pure water. Clean the cap
carefully, without applying much effort, otherwise it may result In water

leakage through the cap.

Once water remains are removed from the surface of the atomizer, wipe It by a
soft cloth.
Clean the external surface of the unit by a damp and soft cloth.

9.Troubleshooting

In case of emergencies resort to troubleshooting methods, given in tables.
If you are unable to solve issues by means of mentioned methods, contact

a service center.Life of the humidifier is 5 years.

Upon expiration of the humidifier it must be disposed in accordance with
regulations, rulesand by means, currently in force at a disposal station.

Tables.

= Deflect

Possible cause

Remedy

Poor atomizing

(insufficient

performance)

The unit is operating in

a light mode (low

atomizing frequency)

No defect If necessary to switch to the intensive

mode, press "Atomizing frequency" button in
the manual setting mode and switch the unit

to the intensive operation mode.

Atomizer is cloaoed

Clean the atomizer

Tank water temperature

is too low

Set the maximum performance. Humidifier's

oerformance will be increased in 10 minutes

No atomizing

The plug is poorly

inserteo into an outlet

Connect the plug into an outlet carefully

Red light on the water

indkaitor has illuminated

and went out (water

tank is completely empt^

Add water to the tank

A white residue appeared

on objects arouncf the

humidifier (salts,

separating from water)

Lime deposits are formed

on the membrane

dean the humidfier^ membrane by a spedal brush

Water demineralization

cartridge is worn down

(ion exchange resin)

Replace the cartridge

No warm atomizing

Use of warm steam is

not selected

Press "warm steam" button in the manual setting

mode and switch the unit to a warm steam

humidification rTKxle

Operation has just started

No defect. It will take about 10-20 minutes

for warm steam to be atomized (time, required

for water heating by the heater after

it's switched on)

Difference between the

level of current humidity

and readings of a

humidity recorder

is too big

Dirt accumulation

inside an air vent

Clean the air vent Even in one room humidity

can be different deoendina on the location

The unit IS operated

k\

places wheie it is affected

by the environment^

for eomple by a window

Install the unit in places, where it cannot be

affected by the environment

Steam has an
unpleasant odor

Not fresh water in use Clean the unit in accordance with the cleaning

and maintenance manual and fill it with fresh

water

There are remains of

not fresh water or litter

in the water groove

Signari"is given

Tankfull sound signal

No defect in the unit keep on its operation

Signal "2” is given

Fan operation

sound signal

Advertising