ENGLISH

Timer to switch off the device

With the mode button MODE (Fig. 2, paragraph 3), seiect the time after
which the device wiii automaticaiiy shut off: the indicator "19" (Fig. 3) - turn
off after 1 hour, the indicator "18" (Fig. 3) - off after 2 hours, the indicator "17"

(Fig. 3) - shut-off after 4 hours. To exit the timer mode and change to other
modes, press the mode button.

Air ionization, air ozonation, the work of an ultraviolet lamp

Pressing Function, you can seiect one of: the work of the ionizer (the

corresponding LED iights up), the work of the ozonator (corresponding

indicator iights up), the work of an uitravioiet iamp (iights up the

corresponding LED), simuitaneous operation of the ionizer and ozonator,
simuitaneous operation of the ionizer and UV iamps, ozone generator and
simuitaneous operation of uitravioiet iamps, the simuitaneous operation of
the ionizer, ozone generator and uitravioiet iamp, turn off ail functions

(ionization, ozonation and uitravioiet iamp).

Select the level of power (fan speed) and night operation

Air has three modes of power, to use the seiect button to switch the fan
speed SPEED: iowfan speed (minimum capacity of the device), the average
fan speed (average power), high fan speed (the maximum capacity of the
device).

The fan speed (iow, medium, high) wiii be dispiayed indicator "15” (Fig. 3).
After pressing the SPEED fan speed varies smoothiy over a short period of
time ranging from 0.5 to 2 seconds.

if you hoid down SPEED for three seconds, the dispiay is oniy one indicator of
night mode "16" (Fig. 3), aii other iights go out. The fan speed is iow. To exit

the SLEEP, press any button.

Timers shelf life of filters

if the indicator is HEPA (n.9,fig. 2), this means that the HEPA filter has fulfilled
its useful life and must be changed. After replacing the filter, click «HEPA
RESET»,

the

timer

starts

counting

a

new

expiration

date

filter.

If the indicator lights CARBON (item 10, Fig. 2), this means that the carbon

Carbon and Photocatalytic PH3 filters (2 in 1 ) exhausted their useful life and

need to be changed. After replacing the filter, click «CARBON RESET», the

timer starts counting a new expiration date filter.

If the indicator lights FIBRE (p. 11, fig. 2), this means that the filter FIBRE

worked his useful life and must be changed. After replacing the filter, click
«FIBRE RESET», the timer starts counting a new expiration date filter.

6. AIR PURIFICATION SYSTEM

Air cleaning system includes: air ionizer, ozone generator, an ultraviolet
lamp, HEPA filter, carbon filter and photocatalyst filter PH3 (2 in 1), FIBRA
filter, filterforfragrance (see Fig. 6).

* To use this filter, apply a small amount of any aromatic substances such as oil on the suriace of the

filter. Aromatic substance in the package is not included.

6.1 .The ionizer generates negative ions (anions) and refreshes the air in the
room. Anions strengthen the nervous and circulatory systems, improve the
lungs and provide effective protection against respiratory illnesses (such as
asthma and pneumonia). Anions purify the air of dust and smoke.

6.2.

Ozone generates ozone. After the interaction with chemical and

microbiological contaminants substances ozone becomes ordinary oxygen.
Ozone kills all known microorganisms such as viruses, bacteria, fungi, and
odors.

o ATTENTION!

When the function of ozonation peopie must necessarily leave the premises
Ozone kilis aii known microorganisms such as vimses, germs, bacteria, fungi, algae,
etc. but it can also have adverse effects on human health.

6.3. UV light breaks down harmful bacteria adhering to the filter (bacteria,

viruses and fungal spores) to simpler compounds, destroying them.

6.4. Filter HEPA (High Efficiency Particulate Air filter) clears the air of dust,
pollen and other allergens down to 0.3 microns in size to 99.95%.

6.5.

Carbon filter and the photocatalyst filter PH3 (2 ini). Charcoal filter

removes cigarette smoke, harmful gases traps (such as carbon monoxide,
and formaldehyde **) and clears the air of odors and other chemical
compounds.

** Formaldehyde - a colorless gaseous substance with a pungent smell, used in many consumer
products (among them - plastics, adhesives, base laminate of MDF and furniture made of chipboard,
MDF, which are used in the manu^cture of formaldehyde resins.

Photocatalyst

filter

effectively

removes

harmful

organic

and

inorganic

pollutants, bacteria and viruses, mold spores. Photocatalyst filter collects
contaminants

and

decompose

them

into

harmless

substances.

Its

maximum efficiency is achieved when working together with an ultraviolet
lamp,

which

is

involved

in

the

process

of

photocatalyst.

The effects of UV harmful organic and inorganic components are oxidized to

carbon dioxide and water.

www.timberk.ru • air purifier 13

Advertising