Table 5.

IMPORTANT!
Useful capacity of an ion exchange filter is about 400 liters. Continuous
use after expiration reduces the capability to filter hard components
(calcium and magnesium) of tap water. As a result, the level of white
residueformation increases.

Standard

filter

replacement

period

is

about

180

days

given

the

automatic operation mode (duration of humidification with heating -
about 6 hours every day). Filter replacement period can be decreased
depending on different frequency of operation and water quality. Pay
attention to the formation of a white powder.

8. CLEANING AND MAINTENANCE OFTHE UNIT

Prior to cleaning make sure that the plug is disconnected from an outlet.

Otherwise it may result in an electric shock. Before cleaning, wait until water

in grooves is completely cooled down in order not to burn hands.

8.1 To wipe the external surface of the unit use a damp and soft cloth. To

prevent an electric shock do not scratch and do not damage unit's elements
upon cleaning.

When cleaning the unit, do not use solvents, benzine, dimethylbenzene, hard

brush, talc powder and other substances other than water.

8.2 Wipe water remains inside the groove under the tank by a damp and soft
cloth. To remove water remains on small parts you can use the brush, and
then wipe them again with a soft cloth. Clean the unit once or twice a week.

8.3 If there is dirt on the membrane, clean It by means of a brush. Clean the

unit once or twice a week.

8.4 Use a brush to remove water remains on the surface of the nozzle and
then wipe it again by a soft cloth. Clean the unit once or twice a week.

8.5 Clean the water tank and the atomizer by pure water. Clean the cap
carefully, without applying much effort, otherwise it may result in water

leakage through the cap.

Once water remains are removed from the surface of the atomizer, wipe it by
a soft cloth. Clean the external surface of the unit by a damp and soft cloth.

Defect

Possible cause

Remedy

Poor atomizing

OnsufHcient

performance)

The unit is operating in

a light mode (low

atomizing frequency)

No def^ If necessary to switch to the intensive

mode, press "Atomizing frequency" button in

the manual setting mode and switch the unit

to the intensive ooeration mode.

Atomizer is cloaqed

Clean the atomizer

Tank water temperature

is too low

Set the maximum performance. Humidifier's

performance will be increased in 10 minutes

No atomizing

The plug is poorly

inserted^into an outlet

Connect the plug into an outlet carefully

Red light on the water

indkaror has illuminated

and went out ^fvater

tank is compleiiely empty)

Add water to the tank

A white residue appeared

on objects around the

humidifier (salts,

separating from water)

Lime deposits are formed

on the membrane

dean the humidifier^ membiane by a special brush

Water demineralization

cartridge is worn down

(ion exchange resin)

Replace the cartridge

Difference between the

level of current humidity

and readings of a

humidity recorder

is too big

Dirt accumulation

inside an air vent

Clean the air vent. Even in one room humidity

can be different deoendino on the location

The unit is operated in

plaoe!» where it is affected

by the environmenil^

for

eanvie,

by a windcw

Install the unit in places, where it cannot be

affected by the environment

Steam has an

unpleasant odor

Not fresh water in use

Clean the unit in accordance with the cleaning

and maintenance manual and fill it with fresh

water

There are remains of

not fresh water or litter

in the water groove

9.TROUBLESHOOTING

In case of emergencies resort to troubleshooting methods, given in tables.
If you are unable to solve issues by means of mentioned methods, contact

a service center.Life of the humidifier is 5 years.

Upon expiration of the humidifier it must be disposed in accordance with
regulations, rules and by means, currently in force at a disposal station.