6. OPERATION OFTHE UNIT
Switching on the unit
Connect the unit to electric mains. Fill the tankwith water in advance.
A musical signal will be given when the unit is connected to a power supply
source.
Press "On/Off" button (Power, On/Off), a musical signal will be given and
the unitwill automatically start operating.
“AUTO" mode will be shown on the display screen and steam will start
coming out of the atomizer.
The display screen will show current air humidity and the warm atomizing
mode will be switched on automatically.
Ten seconds after pressing the power button a light atomizing indicator
(preparation for operation) will be illuminated and then will goout.
At the very beginning of this operation the atomizing level could seem
unstable
which
is
caused
bythetemperaturedifferenceand
waterquality.
It will take some time for water to transform into steam inside the
atomizer's nozzle and this process to be stabilized. In 10-25 minutes of
operation theatomizing level will be gradually stabilized.
Heating of steam will take about 10-20 minutes.
In order to specify the desired level of humidity in the room, press the set
humidity level - an increase (15) or decrease (16). The device will
automatically adjust the intensity oftheirwork to achievea desired level of
humidity you.
In order to regulate the humidity level manually, press (14), the frequency
of the steam will vary. This action will be reflected on the display (9).
The display shows the preset humidity level during the installation and the
current
humidity
level
after
installation
by
the
user.
By clicking on the timer, you can set the time on the instrument off after 1 -
12 hours.
To enable or disable the ionizer press the appropriate button (13).
The ionizer generates negative ions (anions) and refreshes the air in the
room. Anions strengthen the nervous and circulatory systems. Improve
the lungs and provide effective protection against respiratory illnesses
(such as asthma and pneumonia). Anions purifytheairofdustand smoke.
IMPORTANT!
At first or repeated use of the unit even with full tank the water level
indicator, showing there is no water, will be illuminated on the display
screen. It happens due to the fact that it takes some time for water to flow
from the tankto a water groove.
The unitwill automatically startoperating in 2-5 minutes.
In case if all water in the tank is used, the unitwill be switched off and a
sound signal will be given prior to it and the"waterleverindicator will be
illuminated. In five seconds the light indicator will go out and a red light
will be illuminated.
Add water In accordance with the manual forfurther use of the unit.
Switching off the unit
Press On/Off button, the light indicator will go out and the unit will be
switched off.
Disconnect the plug from an outlet.
7. CARTRIDGE FILTER WITH AN ION EXCHANGE RESIN
The set of the unit includes a cartridge filter with an ion exchange resin. Upon
long use of the humidifier without replacement of resin a white residue may
appear on the unit and objects next to it.
The white residue is calcium and magnesium comprised in the composition
of ordinary tap water. When the ion exchange resin in the filter expires, they
are released along with steam and settle on the surrounding objects and
surfaces.Though these substances are safe for people. In large amounts they
may have hazardous effect on furniture. By means of an Ion exchange filter,
installed at the bottom of the tank, calcium and magnesium are removed
from tap water. At the beginning of operation the ion exchange filter can
make water tea-colored.This doesn't affect safety or operation of the unit.
The ion exchange filter is installed at the bottom of the water tank. To replace
the filter it is necessary to remove a cap by turning it counterclockwise and
then remove the filter also by turning it counterclockwise. The new filter is
installed in the reverse order. To purchase an ion exchange filter, please,
contact the seller.