Safety precaution, Warning – Инструкция по эксплуатации Panasonic -ME14CD3P

Страница 13

Advertising
background image

ENGLISH

13

1) This appliance must be earthed.

2) If the supply cord is damaged or needed to be replaced, it must be replaced by authorized

service agent or a similarly qualified person in order to avoid a hazard.

3) Remove power plug or disconnect from the main power supply before servicing this

appliance.

4) Do not repair by yourself.

In case of malfunction of this appliance, do not repair by yourself.
Contact to the sales dealer or service dealer for a repair.

5) Do not use in an explosive atmosphere.

Do not use this appliance in a potentially explosive atmosphere.

6) Turn off the power (Isolation from main power supply).

Pull off the power plug from the receptacle, or switch off the breaker, or switch off power
disconnecting mean to isolate the equipment from the main power supply in case of an
emergency.

Notes
• If the unit is not going to be used for an extended period of time, turn off the main Power

supply. If it is left at the ON position, approximately 14 W of electricity will be used even if
the indoor unit has been turned off with the remote control.

• If operation is stopped, then restart immediately, the unit will resume operation only after 3

minutes.

Use under the following conditions

DBT:Dry Bulb Temp

WBT:Wet Bulb Temp

Maximum Temperature

Minimum Temperature

Cooling

Indoor

DBT

WBT

32

23

16

11

DBT

WBT

43

26

16

11

Outdoor

Indoor

DBT

WBT

WBT

30

2

DBT

24

18

-5

-6

Outdoor

Heating

(Unit in

°C)

* Airborne noise.

A-weighted sound pressure level of this appliance is less than 70dB (A) under the JIS
C 9612 test conditions.

Maximum cooling operation 1 m from the unit

Safety Precaution

WARNING

Advertising
Эта инструкция подходит к следующим моделям: