Door seal
Check from time to time the door seal and
eliminate eventual possible objects that
could be trapped in the fold.

Drain pump
The pump should be inspected regularly
and particularly if:
• the appliance does not empty and/or spin;
• the appliance makes an unusual noise dur-

ing draining due to objects such as safety
pins, coins etc. blocking the pump.

• a problem with water draining is detected

(see chapter “What to do if...” for more de-
tails).

Warning! Before opening the pump
door, switch the appliance off and
remove the mains plug from the socket.

Proceed as follows:
1. Unplug the appliance.
2. If it is necessary, wait until the water

has cooled down.

3. Open the pump door.

4. Place a container close to the pump to

collect any spillage.

5. Pull out the emergency emptying hose,

place it in the container and remove its
cap.

6. When no more water comes out, un-

screw the pump cover by turning it anti-
clockwise and remove the filter. Use pli-
ers, if necessary. Always keep a rag
nearby to dry up any water spillages
when removing the cover.
Clean the filter under a tap, to remove
any traces of fluff.

7. Remove foreign bodies and fluff from

the filter seat and from the pump impel-
ler.

electrolux 17