9

Motor size

Motor OF311

Motor OF312

Voltage

Volt

120

20

20

120

20

20

Frequency

Hz

60

50

60

60

50

60

Power

HP

0,

0,

0,

0,60

0,60

0,60

kW

0,24

0,24

0,24

0,44

0,44

0,44

Displacement

l/min

84

67

84

168

14

168

CFM

2,97

2,7

2,97

5,9

4,7

5,9

FAD @ 8 Bar ***

l/min

4

26

4

64

58

64

CFM

1,20

0,92

1,20

2,26

2,05

2,26

Max. pressure**

Bar

6

6

6

6

6

6

PSI

90

90

90

90

90

90

Max. current

Amps

4,7

2,6

2,7

8,0

,4

,8

Weight

Kg

10

10

10

1

1

1

Lbs

22

22

22

29

29

29

Dimensions (l x w x h)

mm

20 x 140 x 240

20 x 140 x 240

Inch

9.0 x 5.5 x 9.5

12.5 x 5.5 x 9.5

Model

OF301 - 4B

OF302 - 4B

OF302 - 15B

Tank size

liter

4

4

15

US gallon

1,1

1,1

4,0

Weight

kg

19

22

25

lbs

42

49

55

Dimensions (l x w x h)

mm

90 x 10 x 50

90 x 20 x 50

80 x 80 x 50

Inch

15,5 x 12,5 x 1,5

15,5 x 12,5 x 1,5

15,0 x 15,0 x 21,0

Pumping time
(0-8 bar/0-120 psi)

@ 50 Hz sec.

90

45

165

@ 60 Hz sec.

75

40

15

Noise level @ 1 m

@ 50 Hz dB(a)

65

65

65

@ 60 Hz dB(a)

66

66

66

Model

OF302 - 25B

OF302 - 25BD2**

2*OF302 - 40B

2*OF302-40BD2**

Tank size

liter

25

25

40

40

US gallon

6,6

6,6

10,6

10,6

Weight

kg

28



46

59

lbs

62

7

101

10

Dimensions (l x w x h)

mm

80 x 80 x 610

510 x 460 x 610

560 x 450 x 610

560 x 540 x 60

Inch

15,0 x 15,0 x 24,0

20,0 x 18,0 x 24,0

22,0 x 18,0 x 24,0

22,0 x 21,0 x 25,0

Pumping time
(0-8 bar/0-120 psi)

@ 50 Hz sec.

270

25

220

260

@ 60 Hz sec.

225

250

180

220

Noise level @ 1 m

@ 50 Hz dB(a)

65

65

68

68

@ 60 Hz dB(a)

66

66

69

69

**

Displacement is reduced by approx. 18-20% on units with dryer (D). Min. pressure required to operate dryer: 6 bar

Technical modifications reserved.

The figures in the tables are based on the unit working in fairly clean air, at ambient temperatures around 20-40°C, relative humidity
near 50% and operating at sea level. The performance of the product will be adversely effected at high altitudes. For further information
on the wirings isolations class: See data table on the motor.