94

Five-digit display

Cause and/or Corrective Actions

• You are using a battery pack that is not an “InfoLITHIUM”

battery pack.

c Use an “InfoLITHIUM” battery pack. (p. 16)

• Moisture condensation has occurred.

c Remove the cassette and leave your camcorder for at least 1

hour to acclimatize. (p. 105)

• The video heads are dirty.

c Clean the heads using the Sony V8-25CLD cleaning cassette

(not supplied). (p. 106)

• A malfunction other than the above that you can service has

occurred.

c Remove the cassette and insert it again, then operate your

camcorder.

c Disconnect the mains lead of the AC power adaptor or

remove the battery pack. After reconnecting the power
source, operate your camcorder.

• A malfunction that you cannot service has occurred.

c Contact your Sony dealer or local authorized Sony service

facility and inform them of the 5-digit code. (example:
E:61:10)

If you are unable to rectify the problem even if you try corrective actions a few times, contact your
Sony dealer or local authorized Sony service facility.

Your camcorder has a self-diagnosis display function.
This function displays the current condition of your
camcorder as a 5-digit code (a combination of a letter
and figures) in the viewfinder or in the display
window.
If a 5-digit code is displayed, check the following
code chart. The last two digits (indicated by

ss

) will

differ depending on the state of your camcorder.

C:21:ss

viewfinder or display window

Self-diagnosis display

•C:ss:ss

You can service your camcorder
yourself.

•E:ss:ss

Contact your Sony dealer or local
authorized Sony facility.

E:61:ss
E:62:ss

C:31:ss
C:32:ss

C:04:ss

C:22:ss

Self-diagnosis display

English

C:21:00