Auto off, Specifications, Replacement parts – Инструкция по эксплуатации Fluke T5-1000

Страница 2: Accessories, Warning, 45 min

Advertising
background image

Auto Off

45 min

LO

+

+

Do not

overtighten

screw

OFF

2 AA

+

+

Specifications

Specifications subject to change without notice.

Calibration

1-year calibration cycle

Temperature

Operating:

Storage:

-10 °C to +50 °C (14 °F to 122 °F)

-30 °C to +60 °C (-22 °F to +140 °F)

Altitude

Operating:

Storage:

2000 m (6562 ft)

10,000 m (32808 ft)

Relative

Humidity

0 % to 95 %, 5

°C to 30 °C

(41 °F to 86 °F); 0 % to 75 %,

30 °C to 40 °C

(86 °F to 104 °F); 0 % to 45 %,

40 °C to 50 °C

(104

°F to 122 °F)

Battery Type

and Life

AA (2); 360 hours continuous with

alkaline; 125 hours continuous with

zinc chloride

RF Field

Specification

0.5 % full scale + (specified accuracy)

at 3 V / m

Enclosure

Rating

IP 52 per IEC 60529, no vacuum

applied

Temperature

coefficient

0.1 x (specified accuracy) /

°C for <18

°C or >28 °C (< 64.4 °F or > 82.4 °F)

Accuracy

± ( [ % of reading] + [number of least

significant digits] )

Accuracy is specified for 1 year after

calibration, at 18 °C to 28 °C

(64 °F to 82 °F) with relative humidity

to 90 %. AC conversions are ac-

coupled, average responding, and

calibrated to the rms value of a sine

wave input.

Function

T5-600

Range

(600 V

CAT III)

T5-1000

Range

(1000 V

CAT III)

Reso-

lution

Accuracy

600 V

rms

1000 V

rms

1 V

±(1.5 %

+

2 digits)

45 Hz - 66 Hz

600 V

1000 V

1 V

±(1 % + 1 digit)

100.0 A

100.0 A

0.1 A

±(3 % + 3 digits)

45 Hz - 66 Hz

1000

1000

1

±(1 % + 2 digits)

Replacement Parts

Test Lead Assembly.

Replace only with Fluke double-insulated

leads ( ) See "Accessories" for available

probes.

PN 648029

PN 2091779

r

o

o

D

y

r

e

tt

a

B

PN 8758161

w

e

r

c

S

r

o

o

D

y

r

e

tt

a

B

Accessories

H

Use only specified replacement parts.

5 Belt Holster

TP1 Probe Set, Flat-Blade

AC285 SureGrip™ Alligator Clips

AC220 SureGrip™ Alligator Clips

Service Information Sheet, PN 686953

To contact Fluke, call:

USA: 1-800-44-FLUKE (1-800-443-5853)

Canada: 1-800-36-FLUKE (1-800-363-5853)

Europe: +31 402-675-200

Japan: +81-67143114

Singapore: +65-738-5655

Anywhere in the world: +1-425-446-5500

Visit Fluke's Web site at

www.fluke.com

.

Safety ......................... IEC 61010-1: Pollution Degree 2

Electromagnetic

Environment ................ IEC 61326-1: Portable

Warning

Disconnect test leads from power source

before opening battery door.
Před otevřením krytu baterie odpojte od

zdroje napájení měřicí přívody.
Przed otwarciem wnęki baterii należy

odłączyć przewody testowe od źródła

zasilania.
Перед тем как открыть крышку батарейного

отсека, отсоедините измерительные провода.

Pil kapağını açmadan önce test iletkenlerinin

güç kaynağıyla bağlantısını kesin.

Advertising