Material safety data sheet – Инструкция по эксплуатации Sharp AR-201

Страница 83

Advertising
background image

79

Date Issued: Nov. 1, 2000

MATERIAL SAFETY DATA SHEET

MSDS No. F-30991

Section 1. Product Identification

Product
AR-201ND/DV/SD (Black Developer)

Section 2. Supplier’s Name and Address

Sharp Corporation
22-22 Nagaike-cho, Abeno-ku, Osaka, Japan
Local suppliers are listed below. Please contact the nearest supplier for additional information.

(Country) (Name and Telephone Number)

U.S.A. Sharp Electronics Corporation

Telephone number for information: 1-800-237-4277
Emergency telephone number: 1-800-255-3924

Canada Sharp Electronics of Canada Ltd.

Telephone number for information: 905-890-2100
Emergency telephone number: 1-800-255-3924

United Kingdom Sharp Electronics (U.K.) Ltd.

Telephone number for information: 01923-474013

Section 3. Ingredients

Ingredients

CAS No.

Proportion

OSHA PEL

ACGIH TLV

Other Limits

Iron powder 7439-89-6 > 92.5% Not listed Not listed None
Styrene-Acrylate copolymer 29497-14-1 < 7.0% Not listed Not listed None
Carbon black 1333-86-4 < 0.5% 3.5mg/m

3

3.5mg/m

3

None

Section 4. Hazardous Identification (Emergency Overview)

Developer is a black powder containing small amounts of toner, and possessing no immediate hazard.
There are no anticipated carcinogenic effects from exposure based on animal tests performed using toner.

Section 5. Health Hazard Data

Route(s) of Entry:

Inhalation?

Skin?

Ingestion?

No No Possible but very unusual.

Health Hazards: Acute oral toxicity ------------ LDL

0

of this toner which is included in this developer is over

2,000mg/kg.

Mutagenicity ------------------ The toner, which is included in this developer, has been tested on

Ames test. The result is negative.

Carcinogenicity: In 1996 the IARC reevaluated carbon black as a Group 2B carcinogen (possible human

carcinogen). This classification is given to chemicals for which there is inadequate human
evidence, but sufficient animal evidence on which to base an opinion of carcinogenicity. The
classification is based upon the development of lung tumors in rats receiving chronic inhalation
exposures to free carbon black at levels that induce particle overload of the lung. Studies
performed in animal models other than rats did not show any association between carbon
black and lung tumors.
While there have been no studies to date using developer, a two-year cancer bioassay using a
typical toner preparation containing carbon black (a small amount of toner is included in the
developer mixture) demonstrated no association between toner exposure and tumor
development in rats.

Signs and Symptoms of Exposure: Minimal irritation to respiratory tract may occur as with exposure to any

non-toxic dust.

Medical Conditions Generally Aggravated by Exposure: None
Emergency and First Aid Procedures:

Inhalation; Remove to fresh air. If effects occur, consult medical personnel.
Eye; In case of contact, immediately flush eyes with water for 15 minutes.

Advertising