4

GENERAL INTRODUCTION

Humidifier is made of recyclable

plastic of edible grade. It can work

continuously for over 15 hours with

maximum mist intensity. Smooth mist,

power saving, quiet, auto-stop and

long service life are its main features.

HOW IT WORKS

As per the vibrating theory of

ultrasonic

waves,

the

humidifier

divides water drops into particles sized

1 – 5 µm. Then the particles are

diffused by motor-driven devices - fan.

During this course, a large quantity of

anions are produced and diffused.

That’s how this humidifier works to

humidify and refresh the air.

HOW TO USE

A. The best environment temperature

for the humidifier is ranged from 0º to

40ºС. Place it in a room for half an

hour before the first use.

B. It is recommended to use distilled

water. The water temperature should

be no higher than 40ºС.

C. Take the water tank from the

base, open the water lid by turning it

anticlockwise, fill in water, make sure

that the silicon washer is well fitted in

its place and then close the water lid

by turning it clockwise.

D. Connect to power supply and turn

on the switch. Setting proper mist

intensity by turning the mist intensity

controller.

CLEANING AND MAINTENANCE

A. WATER TANK

a. The water tank should be cleaned

frequently. It is recommended to clean

once every 3 days.

b.

Water

should

be

changed

frequently. It should not be kept in the

water tank more than 2 days.

B. TRANSDUCER

Due to geographic factors, water

quality may differ from place to place.

Some places have hard water, which

contains a large quantity of calcium

and magnesium ions. Furthermore,

the use of bleaching powder (to purify

water) also increases the hardness of

water. When this kind of water is used

to humidify the air, calcium and

magnesium ions are diffused together

with the mist. As time goes on, there

will be sediments of scale on the

object

surfaces

and

ground.

Meanwhile,

there

will

also

be

sediments on the transducer and the

water groove, which is to affect the

functioning of the humidifier. To clean

the transducer, please:

a.

Add some cleanser (about 0.5g)

on the transducer, add some water,

and wait for 2-5 minutes.

b.

Use a soft brush to clean the

surface of the transducer. Don’t use

hard tools to scratch its surface.

c.

Use cleanser as packed with the

appliance or other scale cleansers to

be purchased in the market.

d.

Do not use soap or other alkaline

substances to clean the transducer.

C. BASE

a. If the water groove and water

level detector have scale sediments

too, please use the cleanser to clean,

and then wash the water groove with

clean water.

b. Do not immerse the base in water

and make sure that no water enters

the vent.

STORAGE

The original package is the best to

store the unit. Make sure to clean all

the parts and have them dried before

storage. Meanwhile, please loose the

silicon washer to secure its service

life.

DO YOU KNOW

Do you know that different places

have different humidity and, objects

need their own humidity too? Please

find the following:

The Best Humidity for Human Body:

45%RH – 65%RH

The Best Humidity for Disease

Preventing and Treatment: 40%RH –

55%RH

Furniture and Musical Instrument:

40%RH – 60%RH

Computer

and

Communication

Apparatus: 45%RH – 60%RH

Dance Hall, Bar, and Other Public

Places of Entertainment: 40%RH –

65%RH

Library, Art Gallery, Museum: 40%RH

– 60%RH

ATTENTION

Check the household voltage to ensure

it matches the units rated specification

before operating.

A. It is not recommended to use

additives like perfume, essence, etc. It

is

prohibited

to

add

alkaline

substances into the water tank.

B. When working, do not touch the

water in the groove or other parts, lest

electric shock may happen due to

unexpected electric leakage.

C. Do not direct the sprayer nozzle to

children, furniture and walls, etc.

5

Adjust it to empty space instead.

D. Make sure it works far away from

other home appliances.

E. Do not leave it work on unstable

surfaces. When working, do not tilt or

overturn it.

F. In case of abnormal noise or

smell, please turn it off and unplug it

from socket immediately.

G. When cleaning or moving the unit,

please turn it off and remove the

water tank. Shakings may lead to

overflow of water into the base, so as

to affect its function.

H. Do not place it in sun-lighted

places for a long time.

I.

Do not repair or replace parts by

yourself. Send it to professionals or

designated service center for help.

Unauthorized modifications or re-

structure of the humidifier may lead to

inconveniences or dangers.

J.

If it is not to be used for a long

time, please unplug and store it

properly.

TROUBLE SHOOTING

TROUB

-LES

REASONS

POSSIB-LE

SOLU-

TIONS

No

breeze,

no mist

No

power

supply.

Power

switch

is

off.

Water level

of

the

groove

is

too high.

Leakage of

the

water

tank.

Connect to

power

supply.

Turn on the

power

switch.

Lower

the

water level

by reducing

water in the

groove.

Tighten the

water lid.

Breeze,

but no

mist

No water in

the

water

tank.

Water level

detector is

not in the

right

position.

The

temperatur

e of the

unit is too

low.

Fill

water

into

the

water tank.

Re-mount

the

water

level

detector.

Place

the

unit in a

room

for

half an hour

before use.

Odd

mist

smell

Water

in

the tank is

kept for too

long a time.

Clean

the

water tank

and re-fill it

with

clean

water.

Low

intensity

Too

much

water in the

water

groove

Mist

Empty

the

water in the

groove and

place

the

water tank

intensity

controller is

on

the

minimum

side.

Scale

sediments

on

the

transducer

The water

is too cold.

The water

is not clean.

again.

Adjust

the

controller.

Clean

the

transducer

Use water of

ordinary

temperature

.

Clean

the

water tank

and re-fill it

with

clean

water.

Mist

spurts

no high

Mist

intensity

controller is

on

the

minimum

side

Water tank

and

the

base

are

not rightly

touched.

Fan

does

not

work

properly

Adjust

the

controller.

Make

sure

water tank

and

the

base

are

touched

rightly.

Ask

professional

s to check

the

fan

inside

the

base.

Noise

Resonance

caused by

too

less

water in the

water tank.

Resonance

caused by

unstable

surfaces.

Add

water

into

the

water tank.

Lay the unit

on

stable

surfaces.

Technical Data:

Power:

35 W

Rated Voltage:

220-230 V

Rated Frequency:

50 Hz

Rated Current:

0.16 А

Water Tank Capacity:

6 l

Water Evaporation: 400 ml/hour

Set

AIR HUMIDIFIER

1

INSTRUCTION MANUAL WITH

WARRANTY BOOK

1

PACKAGE 1

ENVIRONMENT FRIENDLY DISPO-

SAL

You can help protect the

environment!

Please remember to respect

the local regulations: hand

in the non-working electrical

equipment to an

appropriate waste disposal

center.

The manufacturer reserves the

right to change the specification

and design of goods.

Advertising