8.

Cleaning and maintenance

Before cleaning of the appliance, please, make sure that it is unplugged.

Otherwise, it may result in electric shock.

Before cleaning, please, wait for complete cooling of water in grooves - to

avoid burning your hands.
Clean the appliance once or twice a week.
8.1. Wipe an external surface of the appliance with wet and soft cloth.

To avoid the electric shock, do not scratch and damage elements of the

appliance, while cleaning.

Do not clean the appliance with solvent, gasoline, xylene, scrub brush, talc

powder and other substances, except for water.
8.2. Wipe remaining water within the groove under the tank with wet and
soft cloth.
Water remaining on small components may be wiped by a soft brush. Then
clean these components with soft cloth.
8.3. If the membrane is dirty, clean it with a soft brush.
8.4. Use a soft brush to wipe remaining water on the nozzle surface and then
wipe it again with soft cloth.
8.5. Wash the water tank and diffuser with pure water. Wash the cover
accurately and lightly. Otherwise, it will result in leaking of water through
the cover.
After removing of water from the diffuser surface, wipe it with soft cloth.
Clean the external surface of the appliance with wet and soft cloth.

^ ATTENTION!

To avoid deformation and abrasion of working surfaces, resulting in

lowering of diffusion level or other defects, do not use metal
brushes, razors or talc powder to wipe the nozzle surface.

In case of a heavy shock, the tank may leak.
In case of a water leak, stop the appliance operation immediately

and apply to the service center.

To keep the appliance dry, remove water after cleaning and dry the

water tank and the case.
Make sure that there is no water left within the water tank and the
case.

Before a long pause in use of the appliance, please, dry the tank and

the surfaces, install the tank into the case and pack the humidifier in
a plastic bag, and then - in a box.

Keep the appliance in a room with low humidity.
Keeping of the appliance in undried condition may result in

moldiness.

9.Troubleshooting

In case of emergency, please, use the troubleshooting methods shown in

tables. If it is impossible to solve problems with these methods, apply to the
service center.
Service life of the humidifier is 2 years.
At the end of its service life the humidifier should be utilized in accordance
with regulations and procedures, which are in force at the place of

utilization.

Table 2.

Failure

Possible reason

Correction method

Poor diffusion

(insufficient capacity)

The appliance works in

soft mode (low diffusion

frequency)

There is no failure.

If it is necessary to switch to heavy mode, turn the

controller knob to the extreme right position.

The diffuser is clogged

Clean the diffuser

Too low temperature of

water in the tank

Set the maximum capacity. After a while, the

humidifier capacity will increase

No diffusion

Poor plugging

Plug the appliance accurately

White bloom on objects

around the appliance (salts

from water)

Sediments on the

membrane

Clean the membrane with a special brush

Steam with unpleasant

smell

Stale water is used

Clean the appliance in accordance with cleaning and

maintenance instructions and fill it with fresh water

There are residues of stale

water or garbage in the

groove for water or in the

diffuser

www.timberk.com • ultrasonic humidifier

LIST OF PARTS
1. Air humidifier - 1

2. User's manual - 1

3. Guarantee slip - 1
4. Package - 1

5. Filling of tank with water

To fill the tank - see Figure 2.

Fig. 2

ATTENTION!
To avoid the electric shock, unplug the appliance before dismantling

(removing of the tank)! Do not fill the tank with other liquids, except for

tap water. Other liquids have unfavorable effect upon internal
components and lead to failure.

Do not fill the appliance or the water tank with such additives as

essential oil, flavouring agent, detergent, chemical pharmaceuticals, hot
water (over 40°), etc. Otherwise, the water tank and internal
components will be damaged and get out of order. Do not fill the water
directly in internal part of the appliance or in the diffuser. The presence
of water inside the appliance may result in its failure.

Do not hit or throw the water tank. It may be damaged, which will result

in water leakage. Do not use the appliance in case of heavy shock of the

tank. Apply to the maintenance service or service center immediately.

Fill the tank with pure water every day and keep the appliance clean.

6.

Appliance operation

Switching on/off, control of steam escape intensity

Plug the appliance. Before that, fill the tank with water. Turn the on-and-off

and steam escape intensity controller to the right.

The appliance will switch on, the indication light will flash and steam will
come out from the diffuser. In the very beginning of this operation the
diffusion level may be unstable, which is caused by temperature difference
and water quality. Stabilization of this process will take a short time.

O - On

O

- Off

3l - Night mode

Turning the controller to the right and to the left, you may control the steam

intensity. Higher intensity of steam escape results in stronger and faster air

humidification.

In night mode the device operates with less noise and intensity. Depending

on the ambient temperature, humidification capacity may vary from 80 to

100 ml/h

Relative air humidity for comfortable conditions should be between 40 and

60%. You may define a favourable humidity level on the basis of your own

feelings or use a special device - hygrometer*, measuring a relative humidity

level.

Air flavouring

The appliance is equipped with a chamber for aromatic oil. When the

aromatic oil is added, the air will be flavoured. Aromatic oil is not included in
the delivery set.
7.Cartridge filter with ion exchange resin

The delivery set includes a cartridge filter with ion exchange resin. If the

humidifier is used for a long time without replacement of the filter, there
may be a white bloom on the appliance and on objects near it.

This white bloom is calcium and magnesium contained in conventional tap

water. When the ion exchange resin in the filter is worked out, they escape
with the steam and sediment on surrounding objects and surfaces. Though
these substances are harmless for people, in large quantities they may have
an unfavourable effect upon furniture.

The ion-exchange filter installed on the tank bottom removes calcium and

magnesium from tap water.

In the beginning of operation the ion-exchange filter may tint water with

the colour of tea. It does not affect the appliance safety or operation.

The ion-exchange filter is installed on the bottom of the water tank. If you

need to buy a new filter, apply to a shop assistant.