9

Pressure vessel

Pressure tested at: 4-25 liter:

40-50 liter:

Directions for use
Application

Receiver for compressed air.

Receiver specifications See name plate.
Installation

Tubes, etc. must be made of

suitable materials.

Placement

Observe the working temperature

of the receiver.

Ensure that sufficient room for

inspection/maintenance is

available in a horizontal position.

The receiver must be kept in a

horizontal position.

Corrosion protection

The surface treatment must be

maintained as required.

Internal inspection at least every

5 years.

Drain moisture at least once a week.

Alternation/repair

No welding must be made on

pressurized parts.

Safety valve

Ensures that PS will not be exceeded.

Never adjust to a higher pressure

than PS.

The capacity of the valve must be

calculated in accordance

with the volume of air supplied by

the compressor.

(PS = Maximum working pressure

of the receiver)

Declaration of Conformity

NOTE: The declaration of conformity is only valid for units
operating at 20 V/50 Hz, x400 V/50 Hz, 12 V DC or 24 V DC.

The manufacturer, JUN-AIR International A/S, declares that the
products mentioned in this manual are in conformity with:
• 87/404/EEC - 90/488/EEC - 9/68/EEC Council Directive

relating to Simple Pressure Vessels

• 98/7/EC Machinery Directive
• 89/6/EEC EMC Directive
• 7/2/EEC Low Voltage Directive

Flemming Frisch Andersen
Test and Certification Administrator

24 bar

18.3 bar

Operating manual