Pressure vessel
Pressure tested at: 4-25 liter:
40-50 liter:
Directions for use
Application
Receiver for compressed air.
Receiver specifications See name plate.
Installation
Tubes, etc. must be made of
suitable materials.
Placement
Observe the working temperature
of the receiver.
Ensure that sufficient room for
inspection/maintenance is
available in a horizontal position.
The receiver must be kept in a
horizontal position.
Corrosion protection
The surface treatment must be
maintained as required.
Internal inspection at least every
5 years.
Drain moisture at least once a week.
Alternation/repair
No welding must be made on
pressurized parts.
Safety valve
Ensures that PS will not be exceeded.
Never adjust to a higher pressure
than PS.
The capacity of the valve must be
calculated in accordance
with the volume of air supplied by
the compressor.
(PS = Maximum working pressure
of the receiver)
Declaration of Conformity
NOTE: The declaration of conformity is only valid for units
operating at 20 V/50 Hz, x400 V/50 Hz, 12 V DC or 24 V DC.
The manufacturer, JUN-AIR International A/S, declares that the
products mentioned in this manual are in conformity with:
• 87/404/EEC - 90/488/EEC - 9/68/EEC Council Directive
relating to Simple Pressure Vessels
• 98/7/EC Machinery Directive
• 89/6/EEC EMC Directive
• 7/2/EEC Low Voltage Directive
Flemming Frisch Andersen
Test and Certification Administrator
24 bar
18.3 bar
Operating manual