Technical data – Инструкция по эксплуатации JUN-AIR 8000 series [no cabinet]

Страница 14

Advertising
background image

14

Technical data

Model

1000 motor

Voltage

Volt

100

100

120

20

20

Frequency

Hz

50

60

60

50

60

Power

HP

1,02

1,02

1,02

1,02

1,02

kW

0,75

0,75

0,75

0,75

0,75

Displacement

l/min

88

106

106

88

106

CFM

,11

,74

,74

,11

,74

FAD @ 8 Bar ***

l/min

45

55

55

45

55

CFM

1,59

1,94

1,94

1,59

1,94

Max. pressure**

Bar

8

8

8

8

8

PSI

120

120

120

120

120

Max. current

Amps

9,7

9,7

9,7

5,1

5,4

Weight

Kg

2

2

2

2

2

Lbs

51

51

51

51

51

Dimensions (l x w x h)

mm

450 x 260 x 20

Inch

17,5 x 10,2 x 12,4

Noise level @ 1 m

dB(a)

70

72

72

70

72

Model

1000-25B

1000-25BD2

Tank size

liter

25

25

US gallon

6,6

6,6

Weight

kg

40

49

lbs

88

108

Dimensions (l x w x h) ****

mm

450 x 400 x 620

460 x 650 x 610

Inch

17,7 x 15,7 x 24,4

18,1 x 25,6 x 24,0

Pumping time
(0­8 bar/0­120 psi)

@ 50 Hz

sec.

20

280

@ 60 Hz

sec.

195

20

Noise level @ 1 m

@ 50 Hz

dB(a)

70

70

@ 60 Hz

dB(a)

72

72

* Neutral is required
** Higher pressure available upon request
*** Displacement is reduced by 18­20% on units with dryer. Min pressure required to operate: 6 bar
**** ­phase units are approx. 100 mm wider than 1­phase units

Technical modifications reserved

Technical data

Advertising
Эта инструкция подходит к следующим моделям: